| Os motores de busca de Datasheet de Componentes eletrônicos |
|
TS4601B Folha de dados(PDF) 21 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
TS4601B Folha de dados(HTML) 21 Page - STMicroelectronics |
|
21 / 28 page ![]() TS4601B Application information 21/28 In the volume register, MUTE_L, and MUTE_R are dedicated bits to enable the mute independently from the channel. When MUTE_L, MUTE_R are set to VIH, the mute function is enabled on the corresponding channel. When MUTE_L, MUTE_R are set to VIL, the gain level is applied to the channel. Control register CR0 Amplifier output short-circuit detection: The outputs of the amplifier are protected against short-circuits that might occur accidentally during manipulation of the device. In the typical application, if a short-circuit arises on the jack plug, there is no detection due to the serial resistor present on the amplifier output, thus the output current threshold is not reached. To be active, the detection has to occur directly on the amplifier output with a signal modulation on the inputs of the TS4601B. If a short-circuit is detected on one channel, a flag is raised in the I²C read register CR0. ● SC_L: equals 0 during normal operation, equals 1 when a short-circuit is detected on the left channel ● SC_R: equals 0 during normal operation, equals 1 when a short-circuit is detected on the right channel The corresponding channel output stage is then set to high impedance mode. An I²C read command allows the reading of the SC_L and SC_R flags but does not reset them. An I²C write command has to be sent to reset the flags to 0 and restore normal operation. When the TS4601B is in I²C standby mode, the SC_L and SC_R flags are in an undetermined state. Thermal shutdown protection: A thermal shutdown protection is implemented to protect the device from overheating. If the temperature rises above the thermal junction of 150°C, the device is put into standby mode and a flag is raised in the read register CR0. ● T_SH: equals 0 during normal operation, equals 1 when a thermal shutdown is detected. When the temperature decreases to safe levels, the circuit switches back to normal operation and the corresponding flag is cleared. |
|
Ligação URL |
| ALLDATASHEET é útil para você? [ DONATE ] |
Sobre Alldatasheet | Publicidade | Contato conosco | Privacy Policy | Link para a ficha técnica | roca de Link | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |