| Os motores de busca de Datasheet de Componentes eletrônicos |
|
SIMATICS7-400 Folha de dados(PDF) 69 Page - Siemens Semiconductor Group |
|
|
|||||||||||||||||||||||||||||
SIMATICS7-400 Folha de dados(HTML) 69 Page - Siemens Semiconductor Group |
|
69 / 172 page ![]() SIMATIC S7-300 Function modules SIWAREX P 4/41 Siemens ST 70 News · 2006 4 ■Overview SIWAREX P is a weighing and force measuring system for simple tasks. It can be used for all kinds of industrial measurements. SIWAREX P has the design of the SIMATIC S5-100U program- mable controllers and can be used as a stand-alone device or also integrated directly in a SIMATIC S5-90U, -95U or -100U programmable controller. Note: Bus module available as spare part; see I-button with the acces- sories ordering data. ■Technical specifications SIWAREX P Main applications • Load measurement on cranes • Overload protection • Belt tensioning devices • Platform scales • Fill level (containers/bins) Intrinsically-safe load cell powering Optional (Ex-l) Stand-alone (without SIMATIC) Yes Integration in: • S5-90/-95U/-100U Direct integration • S5-95U/DP (PROFIBUS master) Through ET 200U • S5-115U/-135U/-155U Through ET 200U • S7-300 Through ET 200U • S7-400 Through ET 200U • M7-300 Through ET 200U • M7-400 Through ET 200U •C7 Through ET 200U Communication interfaces SIMATIC S5 bus TTY Process interfaces • Digital outputs 2 limits/fault • Analog output/analog input Yes / No Remote display connection (via serial interface) Yes Gross Measuring properties Error limit according to DIN 1319-1 of full-scale value at 20 °C ± 10 K 0,1 % Internal resolution 20.000 Data format for weight values 2 byte (fixed-point) Number of measurements/second 10 Filter 0.0625 -2 Hz Weighing functions • Weight values Gross •Limits 2 (min./max.) SIWAREX P Integral display and operator panel Yes Module parameterization Built-in LCD + Membrane keyboard IP degree of protection to DIN 60 529; IEC 60 529 IP20 Load cell powering • Supply voltage Us (rated value) 10 V ± 0.5 V DC • Max. supply current ≤ 160 mA or ≤ 115 mA (Ex area) • Permissible load resistance: -RLmin > 60 Ω -RLmax < 4010 Ω With Ex(i) interface: -RLmin > 87 Ω -RLmax < 4010 Ω Permissible load cell characteristic Up to 3 mV/V Permissible range of measuring signal (at greatest set characteristic) 0 to 33 mV Max. distance of load cells 500 m (300 m in Ex area) Supply voltage 24 V DC • Rated voltage 24 V DC • Max. current consumption 300 mA Serial port 1 TTY (serial 20 mA): • Baud rate 9600 baud •Parity straight • No. of data bits/stop bits 8/1 • Signal level Passive, floating • Protocols 3964R / RK512 (send only on request) Binary outputs Number: 2 (relay) Max. switching voltage: 120 V DC 50 V AC Max. current: 1 A (resistive load) |
|
Ligação URL |
| ALLDATASHEET é útil para você? [ DONATE ] |
Sobre Alldatasheet | Publicidade | Contato conosco | Privacy Policy | Link para a ficha técnica | roca de Link | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |