| Os motores de busca de Datasheet de Componentes eletrônicos |
|
SIMATICS7-200 Folha de dados(PDF) 79 Page - Siemens Semiconductor Group |
|
|
|||||||||||||||||||||||||||||
SIMATICS7-200 Folha de dados(HTML) 79 Page - Siemens Semiconductor Group |
|
79 / 172 page ![]() SIMATIC S7-400 Central processing units CPU 416F-2 5/3 Siemens ST 70 News · 2006 5 ■Technical specifications (continued) 6ES7 416-2FK04-0AB0 S7 times -Number 2,048 • Retentivity - adjustable Yes - lower limit 0 - upper limit 2,047 -preset no timers retentive • Timing range - lower limit 10 ms - upper limit 9,990 s IEC timer - available Yes -Type SFB Data areas and their retentive characteristics • Retentive data area as a whole total working and load memory (with backup battery) Flags -Number 16 KByte - adjustable retentivity Yes; MB 0 to MB 16383 - Number of clock memories 8; (1 memory byte) Address area I/O address area - Inputs 16 KByte -Outputs 16 KByte • of which distributed - MPI/DP interface, inputs 2KByte - MPI/DP interface, outputs 2KByte - DP interface, inputs 8KByte - DP interface, outputs 8KByte Process image - Inputs, adjustable 16 KByte - Outputs, adjustable 16 KByte - Inputs, preset 512 Byte - Outputs, preset 512 Byte - Number of component process images, max. 15 - Access to consistent data in the process image Yes - Consistent data, max. 244 Byte Digital channels - Inputs 131,072 -Outputs 131,072 - Inputs, of which central 131,072 - Outputs, of which central 131,072 Analog channels - Inputs 8,192 -Outputs 8,192 - Inputs, of which central 8,192 - Outputs, of which central 8,192 6ES7 416-2FK04-0AB0 Configuration • connectable OP 63 without event processing, 12 with event processing • Central units, max. 1 • Expansion units, max. 21 • Multi-computing Yes; max. 4 CPUs (with UR1 or UR2) IM - Number of pluggable IMs (overall), max. 6 - Number of pluggable IM 460s, max. 6 - Number of pluggable IM 463s, max. 4; IM 463-2 Number of DP masters - integral 2 - via IM 467 4 - via CP 10; CP 443-5 Ext. - Mixed mode of IM + CP permitted No; IM467 cannot be used exter- nally together with CP443-5 - No. pluggable S5 modules (via adapter casing in centr. unit) max 6 Number of FMs and CPs that can be operated (recommendation) -FM limited by the number of slots and by the number of connections - CP, point-to-point CP 440: limited by the number of slots CP 441: limited by the number of connections -CP, LAN limited by the number of connec- tions - PROFIBUS and Ethernet CPs 14; incl. CP 443-5 Ext. and IM 467 Time Clock - Hardware clock (realtime clock) Yes -buffered Yes - Triggering 1ms Run-time meter - Quantity 8 Time synchronization - supported Yes - on MPI, master Yes - on MPI, slave Yes - on DP, master Yes - on DP, slave Yes - in AS, master Yes - in AS, slave Yes S7 message functions • Number of stations that can log on for message functions, max. 12 • Symbol-related messages Yes Number of messages - total, max. 1,024 • Block-related messages Yes • Alarm 8 blocks Yes • Statuses Yes Test and startup functions Status/modify -Variable Yes |
|
Ligação URL |
| ALLDATASHEET é útil para você? [ DONATE ] |
Sobre Alldatasheet | Publicidade | Contato conosco | Privacy Policy | Link para a ficha técnica | roca de Link | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |