| Os motores de busca de Datasheet de Componentes eletrônicos |
|
AFPSWC Folha de dados(PDF) 3 Page - Panasonic Semiconductor |
|
|
|||||||||||||||||||||||||||||
AFPSWC Folha de dados(HTML) 3 Page - Panasonic Semiconductor |
|
3 / 4 page ![]() For Electric Power Monitoring Item Specification Electrical power 0.5% Active electric power Compliant Class 0.5S (IEC 62053-22) *1 Reactive electric power Compliant Class 2 (IEC 62053-23) Current 0.2% *2 * Single-phase three-wire system 2 (N) phase current, three-phase three-wire system 2 (S) phase current, 0.5% Voltage 0.2% * Single-phase three-wire system 2 (N) phase voltage, three-phase three-wire system between 3-1 voltage, three-phase four-wire system line voltage is 0.5% * The tolerances of CT sensor and VT (instrument voltage transformer) are not included. * 1 IEC62053 is the international standard for electrical power measuring devices. * 2 Current less than 5% of rated value may be outside of accuracy assurance range according to CT setting (maximum tolerance: 0.5%). *1 Only CH1 of main unit is available. Only current transformer input is available for CH2 of main unit and expansion unit. *2 Only AKW264100A * Windows is the trademark of Microsoft Corporation in USA and other companies. Google Chrome and Android are the trademarks of Google Inc. Firefox is the trademark of Mozilla Foundation in USA and the other companies. Safari and OS X are the trademark or the registered trademark of Apple Inc. of USA. iOS is the trademark or the registered trademark of Cisco in USA ans the other companies. *1 Use OS and browser with the latest version. *2 System Web is not supported. * The data display range is the numerical value range which can be displayed by the main unit's display section and is not the allowable measurement range. * If the voltage to be measured is not the rated (commercial) frequency, it may take time for THD (total harmonic distortion) to stabilize. * Please use this demand function as your standard. The demand value calculated with this function is not guaranteed. *1 Only AKW264100A Item Data display range Instantaneous power Active −999.99GW to 0.000kW to 999.99GW Reactive Apparent Integral power (import) Active 0.000kWh to 9999.9PWh Reactive Apparent Integral power for each time zone (4 zone ) (import) Active 0.000kWh ~ 9999.9PWh Reactive Apparent Integral power (export) Active 0.000kWh to 9999.9PWh Reactive Integral power for each time zone (4 zone) (export) Active 0.000kWh ~ 9999.9PWh Reactive Current 0.000 to 99.999kA N-phase when 3P4W Voltage (Phase and Line voltage) 0.00 to 999.99kV Power factor −1.000 to 0.000 to 1.000 Frequency 0.00Hz to 99.99Hz Pulse count value 0.000 to 99999999 Power conversion value 0.000kWh to 9999.9PWh Unbalanced current Each phase 0.00% to 300.00% Unbalanced voltage Each phase 0.00% to 300.00% Current THD (total harmonic distortion) Each phase 0.00% to 400.00% Voltage THD (total harmonic distortion) Each phase 0.00% to 400.00% Current harmonics (2nd to 31st) Each phase 0.00% to 400.00% Voltage harmonics (2nd to 31st) Phase 0.00% to 400.00% Line 0.00% to 400.00% Hour-meter measurement ON 0.0h to 99999.9h OFF 0.0h to 99999.9h Standby 0.0h to 99999.9h Maintenance 0.0h to 99999.9h Active Reactive Present demand (Present value (inst. value) / Maximum demand) Apparent 0.000 kW to 999.9MW Active (export) Reactive (export) Current Item Specifications Supply voltage range 100 to 240V AC Rated frequency 50/60Hz Nominal power consumption 15VA(240V AC) Inrush current 30 A or less (240 V AC at 25℃) Allowable momentary power-off time 10ms Ambient temperature Operation: -10 to +50℃ 14 to 122°F Storage: -25 to +70℃ −13 to 158°F Ambient humidity 30 to 85% RH (at 20℃ 68°F) with non-condensing Breakdown voltage(initial) Between the isolated circuits: 2000 V/1 min ● Enclosure - All terminals ● Between primary and secondary insulated circuits (Double insulation is supported) (1) Power supply terminals – other terminals (2) Voltage input terminal – other terminals Insulation resistance(initial) Between the isolated circuits: 100 MΩ or more Vibration resistance 10 to 150 Hz (7.5 minutes/cycle) Single amplitude: 0.75 mm 0.030 in (1 h on 3 axes) 10 to 55 Hz (1 minute/cycle) Single amplitude: 0.375 mm 0.015 in (1 h on 3 axes) Shock resistance Min. 294 m/s2 (5 times on 3 axes) Display method Black-and-white LCD with backlight (graphic form) Display updating time cycle 500, 1000, 2000, 3000 ms (set with setting mode) Power failure memory method Internal memory Sea level altitude Under 2,000 m 6,562 ft Overvoltage category Ⅲ Pollution degree 2 Dimensions W/H/D Main unit: 85×140×65 mm 3.346×5.512×2.559 in Expansion unit: 85×70×65 mm 3.346×2.756×2.559 in Weight Approx. 450 g (Main unit) Approx. 200 g (Expansion unit) Calendar timer *1 Range January 1, 2015 00:00:00 to December 31, 2099 23:59:59 (leap year supported) Time accuracy Monthly accuracy max. 15 sec. (at 25°C) Back up period About 1 month (by secondary battery *When power off after 48-hour or more of power on time, at 23°C) Measurement items Accuracy General specifications ■ Specifications Main unit memory specifications (for AKW264100A) Web server specifications Demand monitoring and specifications Demand type ・IEC61557-12 Compliant demand 1. Sliding block interval demand 2. Fixed block interval demand 3. Current demand Demand monitor input type Current transformer input Pulse input *1 (set with setting mode) Demand time span 1 to 60 min. (set with setting mode) Demand measurement item Present demand Demand data update cycle 1 min. Display Present demand (Active / Reactive / Apparent / Active (export) / Reactive (export) / Current) Saved data Max.demand, Monthly max. demand (Latest 13 months)*2 Simultaneous access number 6 sessions Web browser *1 Windows Google Chrome Mozilla Firefox iOS *2 Safari Google Chrome Android *2 Google Chrome 5-min. instantaneous value Save cycle 5 minutes Saved data R-current, S-current,T-current, N-current, Average of current R-voltage (L1-N), S-voltage (L2-N), T-voltage (L3-N), Average of phase-voltage, RS-voltage (L1-L2), ST-voltage (L2-L3), TR-voltage (L3-L1) Average of line-voltage Pulse count value Write timing Every hour xx:05:05 (fixed) Saved data amount 96 records for 1 file (for one-day) (Max. 60 days) 15-min. instantaneous value Save cycle 15 minutes Saved data All items excluding for harmonics and conversion value for integral active power Write timing Every hour xx:15:05 (fixed) Saved data amount 2976 records for 1 file (for one-month) (Max. 24 months) Demand Save cycle 1 minute Saved data Present demand (active power, reactive power, apparent power, active power(export), reactive power(export)) Pulse conversion value for integral power, Present current demand (1), (2), (3) Write timing Every hour xx:25:05 (fixed) Saved data amount 1000 records for 1 file (Max. 100 files) Power quality Saved data Power interruption, Over voltage, Under voltage, Over current, Under current (with time stamp of event occurrence and occurrence period) Write timing Every hour xx:35:05 (fixed) Saved data amount 1000 records for 1 file (Max. 100 files) Use safely and correctly after carefully reading the product specification manual, user manual, and operational instruction manual. |
|
|
Ligação URL |
| ALLDATASHEET é útil para você? [ DONATE ] |
Sobre Alldatasheet | Publicidade | Contato conosco | Privacy Policy | Link para a ficha técnica | roca de Link | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |