| Os motores de busca de Datasheet de Componentes eletrônicos |
|
EVAL-ADATE304BBCZ Folha de dados(PDF) 8 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
EVAL-ADATE304BBCZ Folha de dados(HTML) 8 Page - Analog Devices |
|
8 / 18 page ![]() User Guide EVAL-ADATE304 EVALUATION BOARD SOFTWARE analog.com Rev. 0 | 8 of 18 SOFTWARE OPERATION The software provides a graphical user interface to control the ADATE304 serial bus. The serial bus provides control for the inter- nal DAC levels and modes of operation of the device, as described in the ADATE304 data sheet. Windows 7 SP1 is required at a minimum. No Mac version is currently available. To start the ADATE304 Evaluation Board Software, follow these steps: 1. Use the Windows search feature to find the ADATE304 Evalua- tion Board Software. 2. When the search displays the ADATE304 Evaluation Board Software, select it. The main ADATE304 Evaluation Board Software window opens as shown in Figure 4. Load the adate304_default.sbus file after startup. The main ADATE304 Evaluation Board Software window pro- vides controls for the main functions of the ADATE304, including access to the DAC registers. The main window of the ADATE304 Evaluation Board Software also includes the following panels: ► The ADATE304 DAC levels panel allows the user to write to the DACs within the ADATE304. ► The single read and write panel allows the user to write single word commands and single register readbacks to or from the ADATE304 if so desired. ► The mode selection controls panel located on the right side of the GUI (see Figure 12), allows the user to configure the settings of the ADATE304. ► The FT reset and clock speed controls are located in the lower right of the GUI (see Figure 4). DAC LEVELS The ADATE304 DAC levels panel, located in the upper-left corner of the user interface, lists all the current settings of the DACs within the ADATE304 (see Figure 9). Each channel has their individual registers, which means each register can be edited individually. Single Write button in Figure 10 can be used to write on both channels at the same time. DAC values in the DAC levels panel can also be changed in real time by clicking on the up-down arrows in the corresponding box. If a Voltage value is selected with the cursor and a value typed into the window, it is changed when either the mouse is clicked on the entry value or the enter key on the keyboard is pressed. Note that the DAC levels or Voltage is limited to the numbers stated in the data sheet. Typing a greater or lesser value than the maximum or minimum value prompts the software to write the maximum or minimum value instead. This is true for Address, CH, and Data as well on single writes/reads. Either the DAC levels or Voltage can be changed and the other changes accordingly. Figure 9. ADATE304 DAC Levels Panel LOAD FILE SETTINGS The Load Settings and Save Settings panel allows the user to load or save register settings for all DAC and control registers for quicker testing, by clicking the Load Settings button or the Save Settings button (see Figure 10). The Load Settings button prompts the user to choose a previously created setup file. The file updates the GUI and writes changed values out to the ADATE304. All DAC Level values and all mode controls can be saved by clicking the Save Settings button. The user is prompted to provide a file name under which all the settings are saved. In the lower left section, clicking on the Single Write button writes the data-word shown in the controls (CH, Address, Data) to the serial bus of ADATE304. The values of the controls can be man- ually changed by placing the cursor in the box and clicking and entering the desired value. The Address and Data controls are in hex while CH is in binary. Inputs on CH can be same with the binary stated on the data sheet. Changes made using single write updates the software corresponding to that change. All inputs made to the controls are written to the device when the Single Write button is clicked. The Single Read button reads back the register that is addressed in its Address text box. The data is shown only in the RDATA indicator, and it is in hexadecimal format only. The Read All button reads back the corresponding register value from the ADATE304 and displays it in the software. This button can be used to check if the chip and the software settings are in sync. Figure 10. Load Settings, Save Settings, Single Read, Single Write, and Read All |
|
|
Ligação URL |
| ALLDATASHEET é útil para você? [ DONATE ] |
Sobre Alldatasheet | Publicidade | Contato conosco | Privacy Policy | Link para a ficha técnica | roca de Link | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |