| Os motores de busca de Datasheet de Componentes eletrônicos |
|
FN4910 Folha de dados(PDF) 20 Page - Renesas Technology Corp |
|
|
|||||||||||||||||||||||||||||
FN4910 Folha de dados(HTML) 20 Page - Renesas Technology Corp |
|
20 / 39 page ![]() ICL3221E, ICL3222E, ICL3223E, ICL3232E, ICL3241E, ICL3243E 4. Application Information FN4910 Rev.25 Page 20 of 38 Dec 2, 2024 powering up. Figure 11 shows a circuit that prevents the ICL32xxE from initiating automatic power-down for 100ms after powering up. The delay gives the slow-to-wake peripheral circuit time to reestablish valid RS-232 output levels. 4.5.3 Automatic Power-Down (ICL3221E, ICL3223E, and ICL3243E Only) Even greater power savings are available by using the ICL3221E, ICL3223E, or ICL3243E’s automatic power-down function. When no valid RS-232 voltages are sensed on any receiver input for 30µs (see Figure 12), the charge-pump and transmitters power down and reduce the supply current to 1µA. Invalid receiver levels occur whenever the driving peripheral’s outputs are shut off (powered down) or when the RS-232 interface cable is disconnected. The ICL32xxE powers back up whenever it detects a valid RS-232 voltage level on any receiver input. The automatic power-down feature provides additional system power savings without changes to the existing operating system. Automatic power-down operates when the FORCEON input is low and the FORCEOFF input is high. Tying FORCEON high disables automatic power-down, but manual power-down is always available with the overriding FORCEOFF input. Table 5 on page 18 summarizes the automatic power-down functionality. Devices with the automatic power-down feature include an INVALID output signal that switches low to indicate that invalid levels have persisted on all of the receiver inputs for more than 30µs (see Figure 13). INVALID switches high 1µs after detecting a valid RS-232 level on a receiver input. INVALID operates in all modes (forced or automatic power-down, or forced on), so it is also useful for systems employing manual power-down circuitry. When automatic power-down is used, INVALID = 0 indicates that the ICL32xxE is in power-down mode. The time to recover from automatic power-down mode is typically 100µs. Figure 12. Definition of Valid RS-232 Receiver Levels Figure 11. Circuit to Prevent Auto Power-Down For 100ms After Forced Power-Up ICL3221E, ICL3223E, ICL3243E FORCEOFF FORCEON Power Master Power-Down Line 1MΩ 0.1µF Management Unit 0.3V -0.3V -2.7V 2.7V Invalid Level - Power-down occurs after 30µs Valid RS-232 Level - ICL32xxE is Active Valid RS-232 Level - ICL32xxE is Active Indeterminate - Power-down may or Indeterminate - Power-down may or may not occur may not occur |
|
Ligação URL |
| ALLDATASHEET é útil para você? [ DONATE ] |
Sobre Alldatasheet | Publicidade | Contato conosco | Privacy Policy | Link para a ficha técnica | roca de Link | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |