2 of 12
RF2472
Rev A11 DS080128
7628 Thorndike Road, Greensboro, NC 27409-9421 · For sales or technical
support, contact RFMD at (+1) 336-678-5570 or sales-support@rfmd.com.
Absolute Maximum Ratings
Parameter
Rating
Unit
Supply Voltage
-0.5 to 4.0
V
Input RF Level
0
dBm
Operating Ambient Temperature
-40 to +85
°C
Storage Temperature
-40 to +150
°C
Parameter
Specification
Unit
Condition
Min.
Typ.
Max.
Overall
T=27°C, VCC=3.0V
Frequency Range
DC to >6000
MHz
2.4GHz LNA Operation
T=27°C, VCC=3.0V, Freq=2440MHz
Gain
13.0
14.6
17.0
dB
Noise Figure
1.5
dB
Input IP3
+8.0
+10.0
+20.0
dBm
Two tones at 1MHz spacing, -15dBm output
Input P1dB
-10
dBm
PCS and K-PCS LNA
Operation
T=27°C, VCC=3.0V, Freq=1960MHz
Gain
16.3
dB
Noise Figure
1.4
dB
Input IP3
+8
dBm
Two tones at 1MHz spacing, -12dBm output
Input P1dB
-12
dBm
4.9GHz to 5.9GHz
LNA Operation
T=27°C, VCC=3.0V,
Freq=4.9GHz to 5.9GHz
Gain
9.0
10.5
11.5
dB
Noise Figure
1.7
1.9
2.0
dB
Power Supply
Operating Voltage
2.7 to 3.6
V
Operating Current
4.0
6.0
8.0
mA
VCC=3.0V, PD=3.0V
<1.0
3.0
μAVCC=3.0V, PD=0V
Caution! ESD sensitive device.
Exceeding any one or a combination of the Absolute Maximum Rating conditions may
cause permanent damage to the device. Extended application of Absolute Maximum
Rating conditions to the device may reduce device reliability. Specified typical perfor-
mance or functional operation of the device under Absolute Maximum Rating condi-
tions is not implied.
RoHS status based on EUDirective2002/95/EC (at time of this document revision).
The information in this publication is believed to be accurate and reliable. However, no
responsibility is assumed by RF Micro Devices, Inc. ("RFMD") for its use, nor for any
infringement of patents, or other rights of third parties, resulting from its use. No
license is granted by implication or otherwise under any patent or patent rights of
RFMD. RFMD reserves the right to change component circuitry, recommended appli-
cation circuitry and specifications at any time without prior notice.