Back Button N12-RRRM-13A00 Datasheet HTML 4Page - XP Power Limited N12-RRRM-13A00 Datasheet HTML 5Page - XP Power Limited N12-RRRM-13A00 Datasheet HTML 6Page - XP Power Limited N12-RRRM-13A00 Datasheet HTML 7Page - XP Power Limited N12-RRRM-13A00 Datasheet HTML 8Page - XP Power Limited N12-RRRM-13A00 Datasheet HTML 9Page - XP Power Limited N12-RRRM-13A00 Datasheet HTML 10Page - XP Power Limited N12-RRRM-13A00 Datasheet HTML 11Page - XP Power Limited N12-RRRM-13A00 Datasheet HTML 12Page - XP Power Limited  
Zoom Inzoom in Zoom Outzoom out
 12 / 12 page
background image
AC-DC POWER SUPPLIES
12
Signals & Controls
16 Jun 2023
Analogue Signals
Digital Signals
Name
Global, On Chassis Local On Module
Description
AC OK
Global AC OK is an isolated transistor of an optocoupler providing a minimum of 5ms
warning of loss of output regulation. The signal is fully isolated and the collector and emitter
must be connected externally. Maximum sink current 2mA. Maximum voltage 60V.
DC OK
Global DC OK is an isolated transistor of an optocoupler providing warning that the output
voltage has fallen below 90% of nominal. The signal is fully isolated and the collector and
emitter must be connected externally. Maximum sink current 2mA. Maximum voltage 60 V.
Module DC OK is a nominal ‘ON’ isolated transistor of an optocoupler which provides a
warning of loss of output regulation on the main output module. Maximum sink current
2mA. Maximum voltage 60V.
Inhibit
Global inhibit is an isolated control signal input which turns the power supply off by
supplying 2 to 5mA into the pin.
Module inhibit signal is an isolated control signal which turns the module off by supplying
2 to 5mA into the pin.
Voltage Program
Non-isolated analogue input, referenced to the module -Sense, pin 1. 0VDC - 5VDC input
will program the module over the range shown in the module table.
Current Share
Connecting pins 3 and 4 of like voltage modules (4 maximum) will force the current to share
between the outputs.
Name
Description
Select Module (PAGE)
Each module can be addressed individually via this PMBus commands.
On/Off (OPERATION)
The command will turn off or turn on the selected module.
Voltage Program (VOUT_COMMAND)
The command will set the output voltage of the selected module. If multiple modules are
connected in parallel, this command will be applied to all paralleled modules.
Maximum Voltage Level (VOUT_MAX)
This command will set an upper limit of the selected output module voltage. If a voltage is
programmed via Voltage Program (VOUT_COMMAND) above to be higher than VOUT max.
This maximum voltage level will take priority and limit the voltage to this set level. If multiple
modules are connected in parallel, this command will be applied to all paralleled modules.
Overvoltage Alarm Set Point (VOUT_OV_FAULT_LIMIT)
The command will set the selected module’s voltage threshold value such that any
measured output voltage above this threshold will signal a fault. If multiple modules are
connected in parallel, this command will be applied to all paralleled modules.
OCP Set Point (IOUT_OC_FAULT_LIMIT)
The command will set the selected module’s current threshold value such that any
measured output current above this threshold will signal a fault. If multiple modules are
connected in parallel, this command will be applied to all paralleled modules.
Output Voltage Readback (READ_VOUT)
This command will return the actual measured output voltage value of the selected module.
Output Current Readback (READ_IOUT)
This command will return the actual measured current voltage value of the selected module.
Unit Temp Readback (READ_TEMPERATURE1)
This command will return the actual measured highest temperature value from the various
monitored points.
XP Power Readback (MFR_ID)
This command will return the XP Power name as the manufacturer.
Stock Key Readback (MFR_MODEL)
This command will return the STOCK KEY of the product and not the model number. This
assumes the product has been configured by XP Power and not via distribution.
Combined Fault Alarm (STATUS_MFR_SPECIFIC)
OCP, SCP, OTP, UVP, OVP
Output Overvoltage Warning (STATUS_VOUT)
This command will signal 3 different output voltage faults. Vout >10% warning of Vprogram,
Vout >15% fault of Vprogram & when a voltage is programmed greater than the overvoltage
set point.
Output Over Current Warning (STATUS_IOUT)
OC Fault & Warning
Over Temp Warning (STATUS_TEMPERATURE)
OT Fault & Warning as set by OT_Fault and OT_Warn.
Fan Fail (Optional) (STATUS_FAN_1_2)
This command will signal 2 different fan fail conditions when the 3 wire fan option has been
selected. Fan speed below 3000RPM fault expected speed and below 5000RPM warning
expected speed.
Series



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12


Folha de dados Download

Go To PDF Page


Ligação URL



ALLDATASHEET é útil para você?  [ DONATE ] 

Sobre Alldatasheet   |   Publicidade   |   Contato conosco   |   Privacy Policy   |   Link para a ficha técnica    |   roca de Link   |   Lista de Fabricantes
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com