Back Button TDA7415CB Datasheet HTML 10Page - STMicroelectronics TDA7415CB Datasheet HTML 11Page - STMicroelectronics TDA7415CB Datasheet HTML 12Page - STMicroelectronics TDA7415CB Datasheet HTML 13Page - STMicroelectronics TDA7415CB Datasheet HTML 14Page - STMicroelectronics TDA7415CB Datasheet HTML 15Page - STMicroelectronics TDA7415CB Datasheet HTML 16Page - STMicroelectronics TDA7415CB Datasheet HTML 17Page - STMicroelectronics TDA7415CB Datasheet HTML 18Page - STMicroelectronics Next Button
Zoom Inzoom in Zoom Outzoom out
 14 / 50 page
background image
Electrical specification
TDA7415CB
14/50
QBASS
Quality Factor (1)
Q1
0.911.1
-
Q2
1.13
1.25
1.38
-
Q3
1.35
1.5
1.65
-
Q4
1.822.2
-
DCGAIN
Bass DC-Gain
DC-mode= off
-1
0
1
dB
DC-mode= on
3.5
4.4
5.5
dB
MID control
GRANGE
Gain Control Range
±13
±15
±17
dB
ASTEP
Step Resolution
0.5
1
1.5
dB
fC
Center Frequency (2)
fC1
450
500
550
Hz
fC2
0.911.1
kHz
fC3
1.35
1.5
1.65
kHz
fC4
1.822.2
kHz
QMID
Quality Factor (2)
Q1
0.511.1
Q2
1.822.2
Treble Control
GRANGE
Gain Control Range
±13
±15
±17
dB
ASTEP
Step Resolution
0.5
1
1.5
dB
fC
Center Frequency (1))
fC1
6.4
10
13.6
kHz
fC2
8.0
12.5
17
kHz
fC3
9.6
15
20.4
kHz
fC4
11.2
17.5
23.8
kHz
ROOM-EQ (Acoustics Notch-filter)
GRANGE
Gain Control Range
-0
…9dB
ASTEP
Step Resolution
Non-uniform, see description
1
-
2
dB
fC
Notch Frequency (1)
fN1
162
180
198
Hz
fN2
180
200
220
kHz
fN3
198
220
242
kHz
fN4
216
240
264
kHz
QEQ
Quality Factor(1)
Q1
0.911.1
Q2
1.822.2
1.
Min and Max values are calculated according to simulation results; Functionality is guaranteed by measuring a directly
correlated parameter
Table 7.
Main signal processing path (continued)
Symbol
Parameter
Test conditions / remark
Min.
Typ.
Max.
Unit



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50


Folha de dados Download

Go To PDF Page


Ligação URL



ALLDATASHEET é útil para você?  [ DONATE ] 

Sobre Alldatasheet   |   Publicidade   |   Contato conosco   |   Privacy Policy   |   Link para a ficha técnica    |   roca de Link   |   Lista de Fabricantes
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com