| Os motores de busca de Datasheet de Componentes eletrônicos |
|
ST7LITEUSX Folha de dados(PDF) 70 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
ST7LITEUSX Folha de dados(HTML) 70 Page - STMicroelectronics |
|
70 / 108 page ![]() ST7LITEUSx 70/108 12.3.2 Operating Conditions with Low Voltage Detector (LVD) TA = -40 to 125°C, unless otherwise specified Notes: 1. Not tested in production. 2. Not tested in production. The VDD rise time rate condition is needed to ensure a correct device power-on and LVD reset release. When the VDD slope is outside these values, the LVD may not release properly the reset of the MCU. 3. LVD and AVD high thresholds must not be selected at the same time. 4. Use of LVD with capacitive power supply: with this type of power supply, if power cuts occur in the application, it is recommended to pull VDD down to 0V to ensure optimum restart conditions. Refer to circuit example in Figure 62 on page 87. 12.3.3 Auxiliary Voltage Detector (AVD) Thresholds TA = -40 to 125°C, unless otherwise specified Notes: 1. LVD and AVD high thresholds must not be selected at the same time. 2. Not tested in production, guaranteed by characterization. Note: Refer to section 7.4.2.1 on page 29 Symbol Parameter Conditions 3) Min Typ Max Unit VIT+(LVD) Reset release threshold (VDD rise) High Threshold Med. Threshold Low Threshold 3.50 3.30 2.50 4.00 3.70 2.65 4.50 4.30 3.30 V VIT-(LVD) Reset generation threshold (VDD fall) High Threshold Med. Threshold Low Threshold 3.30 3.20 2.40 3.80 3.50 2.70 4.40 4.20 3.20 Vhys LVD voltage threshold hysteresis VIT+(LVD)-VIT-(LVD) 150 mV VtPOR VDD rise time rate 2) 4) 20 - µs/V IDD(LVD) 1) LVD/AVD current consumption VDD = 5V 220 µA Symbol Parameter Conditions 1) Min 2) Typ 2) Max 2) Unit VIT+(AVD) 1=>0 AVDF flag toggle threshold (VDD rise) High Threshold Med. Threshold Low Threshold 3.50 3.30 2.50 4.10 3.90 3.00 4.80 4.60 3.50 V VIT-(AVD) 0=>1 AVDF flag toggle threshold (VDD fall) High Threshold Med. Threshold Low Threshold 3.40 3.20 2.40 4.00 3.80 2.90 4.70 4.50 3.40 Vhys AVD voltage threshold hysteresis VIT+(AVD)-VIT-(AVD) 100 mV ∆V IT- Voltage drop between AVD flag set and LVD reset activation VDD fall 0.45 V 1 |
|
Ligação URL |
| ALLDATASHEET é útil para você? [ DONATE ] |
Sobre Alldatasheet | Publicidade | Contato conosco | Privacy Policy | Link para a ficha técnica | roca de Link | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |