26 / 35 page ![]() DER-18 DVD Recorder Supply – TOP245P March 30, 2004 Page 26 of 35 Power Integrations Tel: +1 408 414 9200 Fax: +1 408 414 9201 www.powerint.com 10.4 Load Transient Response (Load Step) In the figures shown below, signal averaging was used to enable better viewing of the load transient response. The oscilloscope was triggered using the load current step as a trigger source. Since the output switching and line frequency occur essentially at random with respect to the load transient, contributions to the output ripple from these sources will average out, leaving the contribution only from the load step response. At 5Vsb output Figure 15 – Transient Response, 90 VAC, 1.2A- 1.7A Load Step. Top: Output Voltage 1V, 1 ms / div Bottom: Load Current 2 A/div |
|
Ligação URL |
| ALLDATASHEET é útil para você? [ DONATE ] |
Sobre Alldatasheet | Publicidade | Contato conosco | Privacy Policy | Link para a ficha técnica | roca de Link | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|