| Os motores de busca de Datasheet de Componentes eletrônicos |
|
TBL Folha de dados(PDF) 2 Page - TRACO Electronic AG |
|
|
|||||||||||||||||||||||||||||
TBL Folha de dados(HTML) 2 Page - TRACO Electronic AG |
|
2 / 3 page ![]() http://www.tracopower.com Page 2 of 3 Industrial Power Supplies TBL Series 15 to 150 Watt Input Specifications Input voltage – AC nominal rated 100 – 240 VAC; 50/60 Hz TBL 150 models: 100 – 120 / 220 – 240 VAC; 50/60 Hz – AC range (designed for) 85 – 264 VAC; 47 – 63 Hz TBL 150 models: 85 – 132 / 187 – 264 VAC; 47 – 63 Hz – Power derating at low input voltage 5% below 90 VAC Harmonic limits EN 61000-3-2, Class A Recommended circuit breaker (characteristic C or slow blow fuse) 6.0 A Output Specifications Output voltage adjustable range 5 VDC model: 5.0 – 5.2 VDC 12 VDC models: 12 – 16 VDC 24 VDC models: 24 – 28 VDC Output regulation 1 % Ripple and noise (20MHz bandwidth) <100 mV pk-pk Electronic short circuit protection current limitation at 100 – 150 % typ. (automatic recovery) Overvoltage protection, trigger point 5 VDC model: 5.5 – 7.5 VDC 12 VDC models: 16 – 24 VDC TBL 030-124, TBL 150-124: 30 – 37 VDC TBL 015-124, TBL 060-124, TBL 090-124: 29 – 44 VDC Status indicator Bi-colour LED (green: normal operation, red: overload or short circuit) Hold-up time min. 10 ms (115 VAC), min. 20 ms (230 VAC) General Specifications Temperature ranges – Operating –25°C to +70°C max. (with derating) – Storage –40°C to +85°C max. Power derating 2.5 %/K above 60°C Humidity (non condensing) 5 – 95 % rel. H Temperature coefficient 0.02 %/K Reliability, calculated MTBF at +25°C acc. to IEC 61709 TBL 015: >1.5 Mio h TBL 060: >2.1 Mio h all other models: >1.3 Mio h Isolation voltage (60 s) – Input to Output 3000 VAC Safety standards – UL certificate of compliance UL 508 listed UL 1310, class II (15 – 90 W models) – CB test certificate IEC 60950-1 IEC/EN 61010-1, IEC/EN 61010-2-201 – SIQ type approved EN 60950-1 IEC/EN 61010-1, IEC/EN 61010-2-201 EN 50178, EN 60204-1, EN 61558-2-16 – CSA certificate of compliance CAN/CSA-C22.2 No. 60950-1-07 2nd Ed UL 60950-1 2nd Ed – Certification documents www.tracopower.com/overview/tbl Electromagnetic compatibility (EMC), emissions EN 61000-6-3 – Conducted RI suppression on input EN 55022 class B – Radiated RI suppression EN 55022 class B Electromagnetic compatibility (EMC), immunity EN 61000-6-2 – Electrostatic discharge (ESD) EN 61000-4-2 4 kV / 8 kV criteria B – Radiated RF field immunity EN 61000-4-3 10 V/m criteria A – Electrical fast transient / burst immunity EN 61000-4-4 ±2 kV criteria B – Surge immunity line – ground EN 61000-4-5 2 kV criteria B – Surge immunity line – line EN 61000-4-5 1 kV criteria B – Immunity to conducted RF disturbances TBL 90/150: EN 61000-4-6 3 V criteria A – Immunity to conducted RF disturbances other models: EN 61000-4-6 10 V criteria A – Magnetic field immunity EN 61000-4-8 100 A/m criteria A – Mains voltage dips and interruptions EN 61000-4-11 – Voltage Sag immunity SEMI F47-0706 |
|
|
Ligação URL |
| ALLDATASHEET é útil para você? [ DONATE ] |
Sobre Alldatasheet | Publicidade | Contato conosco | Privacy Policy | Link para a ficha técnica | roca de Link | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |