| Os motores de busca de Datasheet de Componentes eletrônicos |
|
STUSB1702 Folha de dados(PDF) 11 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
STUSB1702 Folha de dados(HTML) 11 Page - STMicroelectronics |
|
11 / 38 page ![]() • Undervoltage and overvoltage protections • Reverse current and reverse voltage protections Figure 4. VCONN to CC1 and CC2 power switch protections Current limit programming The current limit can be set within the range 100 mA to 600 mA by a step of 50 mA. The default current limit is programmed through NVM programming (see Section 6 Start-up configuration) and can be changed by software through the I²C interface. At power-on or after a reset, the current limit takes the default value preset in the NVM. Fault management The table below summarizes the different fault conditions that could occur during switch operation and the associated responses. An I²C alert is generated when a fault condition happens. Table 6. Fault management conditions Fault types Fault conditions Expected actions Short-circuit CC output pin shorted to ground via very low resistive path causing rapid current surge Power switch limits the current and reduces the output voltage. I²C alert is asserted immediately thanks to VCONN_SW_OCP_FAULT bits Overcurrent CC output pin connected to a load that sinks current above programmed limit Power switch limits the current and reduces the output voltage. I²C alert is asserted immediately thanks to VCONN_SW_OCP_FAULT bits Overheating Junction temperature exceeding 145 °C due to any reason Power switch is disabled immediately until the temperature falls below 145 °C minus hysteresis of 15 °C. I²C alert is asserted immediately thanks to THERMAL_FAULT bit. The STUSB1702 goes into transient error recovery state Undervoltage VCONN input voltage drops below UVLO threshold minus hysteresis Power switch is disabled immediately until the input voltage rises above the UVLO threshold. I²C alert is asserted immediately thanks to VCONN_PRESENCE bit Overvoltage CC output pin voltage exceeds maximum operating limit of 6.0 V Power switch is opened immediately until the voltage falls below the voltage limit. I²C alert is asserted immediately thanks to VCONN_SW_OVP_FAULT bits STUSB1702 VCONN supply DS12664 - Rev 1 page 11/38 |
|
Ligação URL |
| ALLDATASHEET é útil para você? [ DONATE ] |
Sobre Alldatasheet | Publicidade | Contato conosco | Privacy Policy | Link para a ficha técnica | roca de Link | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |