31 / 73 page ![]() DocID024986 Rev 14 31/73 VL6180 Ranging specification 69 3 Ranging specification 3.1 Proximity ranging (0 to 100mm) The following table specifies ranging performance up to 100mm. These results are derived from characterization of both typical and corner samples (representative of worst case process conditions). Unless specified otherwise, all results were performed at room temperature (23°C), nominal voltage (2.8V) and in the dark. Results are based on the average of 100 measurements for a 17% reflective target @ 50mm. 3.1.1 Max range vs. ambient light level The data shown in this section is worst case data for reference only. Table 14 shows the worst case maximum range achievable under different ambient light conditions. Table 13. Ranging specification 0 to 100mm Parameter Min. Typ. Max. Unit Noise(1) 1. Maximum standard deviation of 100 measurements - - 2.0 mm Range offset error(2) 2. Maximum offset drift after 3 reflow cycles. This error can be removed by re-calibration in the final system -- 13 mm Temperature dependent drift (3) 3. Tested over optimum operating temperature range (see Table 20.: Normal operating conditions) -9 15 mm Voltage dependent drift (4) 4. Tested over optimum operating voltage range (see Table 20.: Normal operating conditions) -3 5 mm Convergence time (5) 5. Based on a 3% reflective target @ 100 mm -- 15 ms Table 14. Worst case max range vs. ambient 0 to 100mm(1)(2) 1. Tested in an integrating sphere (repeatable lab test, not representative of real world ambient light) at 1 kLux and 5 kLux (halogen light source) using 80 x 80 mm targets. Due to high IR content, 5 kLux halogen light approximates to 10 kLux to 15 kLux natural sunlight. 2. SNR limit of 0.1 applied. Note: maximum range could be increased by reducing the SNR limit to 0.06 Target reflectance In the dark(3) 3. Also applicable to lighting conditions with low IR content e.g typical office fluorescent lighting Worst case indoor light (1 kLux diffuse halogen) High ambient light (5 kLux diffuse halogen) Unit 3% > 100 > 80 > 40 mm 5% > 100 > 90 > 45 mm 17% > 100 > 100 > 60 mm 88% > 100 > 100 > 70 mm |
|
Ligação URL |
| ALLDATASHEET é útil para você? [ DONATE ] |
Sobre Alldatasheet | Publicidade | Contato conosco | Privacy Policy | Link para a ficha técnica | roca de Link | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |