7 / 64 page ![]() Description 2/7 Siemens I 2.1 · 2001 General Data Miniature Circuit-Breakers (MCBs) s Tripping characteristics acc. to EN 60 898, DIN VDE 0641 Part 11 Tripping characteristic A • For limited semiconductor protection • Protection of measuring cir- cuits with transformers • Protection of circuits with long cable lengths which will re- quire tripping within 0.4 s acc. to DIN VDE 0100 Part 410 Tripping characteristic B • Cable and line protection mainly in residential buildings, proof regarding shock-hazard protection is not necessary Tripping characteristic C • Cable and line protection, ad- vantageous in case of higher inrush currents, e.g. lamps, motors etc. Tripping characteristic D • The tripping range has been matched to applications in- volving equipment generating significant pulses (transform- ers, solenoid valves) I2-6663b 12 3 4 6 8 10 20 30 1,5 5 15 6 4 2 1 0,2 0,1 0,01 0,02 0,04 0,06 0,4 0,6 10 20 40 1 2 4 6 10 20 40 60 120 1,13 1,45 Multiple of rated current A 12 3 4 6 8 10 20 30 1,5 5 15 I2-6352c 1,13 1,45 6 4 2 1 0,2 0,1 0,01 0,02 0,04 0,06 0,4 0,6 10 20 40 1 2 4 6 10 20 40 60 120 Multiple of rated current A 12 3 4 6 8 10 20 30 1,5 5 15 I2_06353c 6 4 2 1 0,2 0,1 0,01 0,02 0,04 0,06 0,4 0,6 10 20 40 1 2 4 6 10 20 40 60 120 1,13 1,45 Multiple of rated current A 12 3 4 6 8 10 20 3 1,5 5 15 I2_06354c 6 4 2 1 0,2 0,1 0,01 0,02 0,04 0,06 0,4 0,6 10 20 40 1 2 4 6 10 20 40 60 120 1,13 1,45 Multiple of rated current A At other ambient temperatures, the currents of the delayed trip- ping change by approximately 5 % for each 10 K temperature difference. More specifically they increase for temperatures below 30°C and decrease for temperatures above 30° C. For DC, the limit currents of the instantaneous tripping increase by a factor of 1.2. If more than one circuit in a series of MCBs is loaded, this has an impact on the character- istic as a result of an increased ambient temperature. In this case, an additional cor- rection factor must be applied, referred to the rated miniature circuit-breaker current. Number 1 2 - 3 4 - 6 > 7 Correction factor K 1.00 0.90 0.88 0.85 i21_01.fm Seite 7 Mittwoch, 20. Juni 2001 10:09 10 |
|
Ligação URL |
| ALLDATASHEET é útil para você? [ DONATE ] |
Sobre Alldatasheet | Publicidade | Contato conosco | Privacy Policy | Link para a ficha técnica | roca de Link | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |