Thermal protection adjustment
range
0.18…9 A
Thermal overload class
Class 5…30
Reset
Remotely or automatically
Irms rated making capacity
250 A 440 V IEC 60947
Rated breaking capacity
250 A 440 V IEC 60947
[Icw] rated short-time withstand
current
210 A 104 °F (40 °C) - 1 s
105 A 104 °F (40 °C) - 10 s
61 A 104 °F (40 °C) - 1 min
30 A 104 °F (40 °C) - 10 min
Average impedance
2.5 mOhm - Ith 15 A 50 Hz
Power dissipation per pole
0.2 W AC-3 - Ith 9 A
0.56 W AC-1 - Ith 15 A
[Uc] control circuit voltage
24 V DC supplied by the bus coupler
Current consumption
160 mA contactor sealed
160 mA contactor closing
Power dissipation in W
3.5 W at Ie
Complementary
Mechanical durability
30 Mcycles
Electrical durability
2 Mcycles 9 A AC-3 440 V
1.2 Mcycles 15 A AC-1 440 V
Maximum operating rate
3600 cyc/mn AC-3
Operating time
< 100 ms closing
< 30 ms opening
Safety performance level
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Protection type
Thermal overload protection
Motor overheat
Overcurrent
Undercurrent
Jam
Long start
Stall
Rapid cycle lockout
Phase sequence
Rapid restart lockout
Phase reversal
Phase loss
Phase unbalance
Ground current
Monitoring type
Time device ON
Time device switch ON
Number of faults
Number of switching cycles
Number of device power cycles
Average current Iavg
Average voltage Vavg
Max current Imax
Max voltage Vmax
Active and reactive power with voltage module
Active and reactive energy with voltage module
True power factor with voltage module
Local signalling
for DS (device status) 1 LED (green/red)
for LS (load status) 1 LED (green/red)
Standards
EN/IEC 60947-1
EN/IEC 60947-4-1
UL 60947-4-1
CSA C22.2 No 60947-4-1
Product certifications
EAC
CSA
CCC
UL
Mounting mode
Horizontal and vertical 35 mm symmetrical DIN rail)
Connections - terminals
screw-clamp terminals 1 0.00…0.01 in² (1…4 mm²) AWG 16...AWG 12)rigid
screw-clamp terminals 2 0.00…0.01 in² (1…4 mm²) AWG 16...AWG 12)rigid
2
May 9, 2022



Html Pages

1 2 3 4


Folha de dados Download

Go To PDF Page


Ligação URL



ALLDATASHEET é útil para você?  [ DONATE ] 

Sobre Alldatasheet   |   Publicidade   |   Contato conosco   |   Privacy Policy   |   Link para a ficha técnica    |   roca de Link   |   Lista de Fabricantes
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com