Os motores de busca de Datasheet de Componentes eletrônicos
  Portuguese  ▼
ALLDATASHEETPT.COM

X  

DS1720S/T&R Folha de dados(PDF) 2 Page - Maxim Integrated Products

Nome de Peças DS1720S/T&R
Descrição Electrónicos  ECON-Digital Thermometer and Thermostat
PDF  14 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Fabricante Electrônico  MAXIM [Maxim Integrated Products]
Página de início  https://www.maximintegrated.com/en.html
Logo MAXIM - Maxim Integrated Products

DS1720S/T&R Folha de dados(HTML) 2 Page - Maxim Integrated Products

  DS1720S/T&R Datasheet HTML 1Page - Maxim Integrated Products DS1720S/T&R Datasheet HTML 2Page - Maxim Integrated Products DS1720S/T&R Datasheet HTML 3Page - Maxim Integrated Products DS1720S/T&R Datasheet HTML 4Page - Maxim Integrated Products DS1720S/T&R Datasheet HTML 5Page - Maxim Integrated Products DS1720S/T&R Datasheet HTML 6Page - Maxim Integrated Products DS1720S/T&R Datasheet HTML 7Page - Maxim Integrated Products DS1720S/T&R Datasheet HTML 8Page - Maxim Integrated Products DS1720S/T&R Datasheet HTML 9Page - Maxim Integrated Products Next Button
Zoom Inzoom in Zoom Outzoom out
 2 / 14 page
background image
DS1720
2 of 14
ORDER INFORMATION
ORDERING
NUMBER
PACKAGE
MARKING
DESCRIPTION
DS1720S+
DS1720 (see note)
DS1720 in Lead-Free 208mil 8-pin SO
DS1720S+T&R
DS1720 (see note)
DS1720 in Lead-Free 208mil 8-pin SO, 2500 Piece
Tape-and-Reel
DS1720S
DS1720
DS1720 in 208mil 8-pin SO
DS1720S/T&R
DS1720
DS1720 in 208mil 8-pin SO, 2500 Piece Tape-and-Reel
Note: A “+” symbol will also be marked on the package near the Pin 1 indicator.
OPERATION–MEASURING TEMPERATURE
A block diagram of the DS1720 is shown in Figure 1. The DS1720 measures temperatures through the
use of an on–board proprietary temperature measurement technique. A block diagram of the temperature
measurement circuitry is shown in Figure 2.
The DS1720 measures temperature by counting the number of clock cycles that an oscillator with a low
temperature coefficient goes through during a gate period determined by a high temperature coefficient
oscillator. The counter is preset with a base count that corresponds to –5
5°C. If the counter reaches zero
before the gate period is over, the temperature register, which is also preset to the –5
5°C value, is
incremented, indicating that the temperature is higher than –5
5°C. At the same time, the counter is then
preset with a value determined by the slope accumulator circuitry. This circuitry is needed to compensate
for the parabolic behavior of the oscillators over temperature. The counter is then clocked again until it
reaches zero. If the gate period is still not finished, then this process repeats.
The slope accumulator is used to compensate for the nonlinear behavior of the oscillators over
temperature, yielding a high resolution temperature measurement. This is done by changing the number
of counts necessary for the counter to go through for each incremental degree in temperature. To obtain
the desired resolution, therefore, both the value of the counter and the number of counts per degree C (the
value of the slope accumulator) at a given temperature must be known.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14


Folha de dados Download

Go To PDF Page


Ligação URL



ALLDATASHEET é útil para você?  [ DONATE ] 

Sobre Alldatasheet   |   Publicidade   |   Contato conosco   |   Privacy Policy   |   Link para a ficha técnica    |   roca de Link   |   Lista de Fabricantes
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com