6 / 12 page ![]() 6 ABC600 Series tech.support@psbel.com Figure 4. I2C Bus to DSP The sensor commands shall meet the following accuracy requirements: READ_IIN < 0.5 A +/-20% It is for corresponding to max input current READ_IOUT +/-5% +/-2.5 A It is for corresponding to max output current READ_VIN +/-3% +/-2.5 V It is for corresponding to max input voltage READ_VOUT +/-2% +/-2% READ_PIN - - - +/-20% It is for corresponding to max input power READ_POUT +/-5 % +/-5% It is for corresponding to max output power |
|
|
Ligação URL |
| ALLDATASHEET é útil para você? [ DONATE ] |
Sobre Alldatasheet | Publicidade | Contato conosco | Privacy Policy | Link para a ficha técnica | roca de Link | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|