| Os motores de busca de Datasheet de Componentes eletrônicos |
|
R7D-YS2/UL Folha de dados(PDF) 8 Page - M-System Co.,Ltd. |
|
|
|||||||||||||||||||||||||||||
R7D-YS2/UL Folha de dados(HTML) 8 Page - M-System Co.,Ltd. |
|
8 / 38 page ![]() MODEL: R7D R7D SPECIFICATIONS ES-7802 Rev.21 Page 8/38 http://www.m-system.co.jp/ ■ R7D-PA8 The table below shows data allocation of R7D-PA8. Parameter preset and other settings are available with command setting of R7D-PA8. Set the commands according to the procedure explained next. Parameter of each channel is two-word integer not signed. Make sure that data is written or read in a two-word unit. When overflowing, the value to which response can be set is “0” or “1”. The maximum range available is 1000 to 4294967295. (Factory setting: 9999999) Parameters may be preset to a value between the overflow response value and the maximum value. Begin +0 +1 +2 Data to write (upper) CH0 Data to write (lower) CH0 Data to write (upper) CH1 Data to write (lower) CH1 Data to write (upper) CH2 Data to write (lower) CH2 Data to write (upper) CH3 Data to write (lower) CH3 Data to write (upper) CH4 Data to write (lower) CH4 Data to write (upper) CH5 Data to write (lower) CH5 Data to write (upper) CH6 Data to write (lower) CH6 Data to write (upper) CH7 Data to write (lower) Extension discrete output data – Command setting • Command address CH0: Bit 0, 1 CH1: Bit 2, 3 CH2: Bit 4, 5 CH3: Bit 6, 7 CH4: Bit 8, 9 CH5: Bit 10, 11 CH6: Bit 12, 13 CH7: Bit 14, 15 • Command 00: Read data 01: Preset 10: Overflow response value 11: Maximum value CH7 OUTPUT DATA INPUT DATA +3 0 15 +4 +5 +6 +7 +8 0 15 +9 +10 +11 +12 +13 +14 +15 +16 +17 +18 Begin + 0 +1 +2 Data to read (upper) CH0 Data to read (lower) CH0 Data to read (upper) CH1 Data to read (lower) CH1 Data to read (upper) CH2 Data to read (lower) CH2 Data to read (upper) CH3 Data to read (lower) CH3 Data to read (upper) CH4 Data to read (lower) CH4 Data to read (upper) CH5 Data to read (lower) CH5 Data to read (upper) CH6 Data to read (lower) CH6 Data to read (upper) CH7 Data to read (lower) Extension discrete input data Status Command setting • Command address CH0: Bit 0, 1 CH1: Bit 2, 3 CH2: Bit 4, 5 CH3: Bit 6, 7 CH4: Bit 8, 9 CH5: Bit 10, 11 CH6: Bit 12, 13 CH7: Bit 14, 15 • Command 00: Read data 01: Preset 10: Overflow response value 11: Maximum value CH7 +3 +4 +5 +6 +7 +8 +9 +10 +11 +12 +13 +14 +15 +16 +17 +18 |
|
Ligação URL |
| ALLDATASHEET é útil para você? [ DONATE ] |
Sobre Alldatasheet | Publicidade | Contato conosco | Privacy Policy | Link para a ficha técnica | roca de Link | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |