M6SXF2-Z1S2V2-R Folha de dados(PDF) 5 Page - M-System Co.,Ltd.

Nome de Peças M6SXF2-Z1S2V2-R
Descrição Electrónicos  Tension-Clamp Ultra-Slim Signal Conditioners M6S Series
PDF  5 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Fabricante Electrônico  MSYSTEM [M-System Co.,Ltd.]
Página de início  https://www.m-system.co.jp/
Logo MSYSTEM - M-System Co.,Ltd.

M6SXF2-Z1S2V2-R Folha de dados(HTML) 5 Page - M-System Co.,Ltd.

  M6SXF2-Z1S2V2-R Datasheet HTML 1Page - M-System Co.,Ltd. M6SXF2-Z1S2V2-R Datasheet HTML 2Page - M-System Co.,Ltd. M6SXF2-Z1S2V2-R Datasheet HTML 3Page - M-System Co.,Ltd. M6SXF2-Z1S2V2-R Datasheet HTML 4Page - M-System Co.,Ltd. M6SXF2-Z1S2V2-R Datasheet HTML 5Page - M-System Co.,Ltd.  
Zoom Inzoom in Zoom Outzoom out
 5 / 5 page
background image
MODEL: M6SXF3
M6SXF3 SPECIFICATIONS
ES-7990 Rev.4 Page 5/5
http://www.m-system.co.jp/
FUNCTIONS
■ CONTROL LOGIC
The control input can be chosen either hold at open or hold at close by using the PC Configurator Software.
For detailed information on the PC Configuration, refer to the M6CFG users manual.
■ TRACK/HOLD
When the control input is TRACK, the output follows proportionally to the input.
When the control input turns to HOLD, the output at the point of command is held indefinitely.
■ PEAK HOLD
• Peak hold
When the control input is TRACK, the output follows proportionally to the input.
When the control input is HOLD, the output is held at the maximum input value.
When the maximum input value is updated, the output changes to that value.
• Valley hold
When the control input is TRACK, the output follows proportionally to the input.
When the control input is HOLD, the output is held at the minimum input value.
When the minimum input value is updated, the output changes to that value.
• Peak-to-peak hold
When the control input is TRACK, the output follows proportionally to the input.
When the control input is HOLD, the output is held at the maximum peak-to-peak input value (max. value – min. value).
For example, the output is 20% if the maximum input value is 60% and the minimum input value is 40%.
When the maximum peak-to-peak input value is updated, the output changes to that value.
Specifications are subject to change without notice.



Html Pages

1 2 3 4 5


Folha de dados Download

Go To PDF Page


Ligação URL



ALLDATASHEET é útil para você?  [ DONATE ] 

Sobre Alldatasheet   |   Publicidade   |   Contato conosco   |   Privacy Policy   |   Link para a ficha técnica    |   roca de Link   |   Lista de Fabricantes
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com