| Os motores de busca de Datasheet de Componentes eletrônicos |
|
M2MNV-21-R2 Folha de dados(PDF) 5 Page - M-System Co.,Ltd. |
|
|
|||||||||||||||||||||||||||||
M2MNV-21-R2 Folha de dados(HTML) 5 Page - M-System Co.,Ltd. |
|
5 / 6 page ![]() MODEL: M2MNV M2MNV SPECIFICATIONS ES-5095 Rev.9 Page 5/6 http://www.m-system.co.jp/ SWITCHING OPERATIONS 1 2 4 5 7 8 1 2 4 5 7 8 Current Signal (no receiving resistor) Power : OFF Switching command : OFF (open) 1 2 4 5 7 8 1 2 4 5 7 8 Power : ON Switching command : OFF (open) 1 2 4 5 7 8 1 2 4 5 7 8 Power : ON Switching command : ON (short) Current Signal (receiving resistor 50 Ω) Voltage Signal Current Signal (no receiving resistor) Transition (ON to OFF, OFF to ON) Status Power : ON Switching command : OFF to ON or Power : ON Switching command : ON to OFF Current Signal (receiving resistor 50 Ω) Voltage Signal *1. Resistor is provided only for the input code 2: Current signal (receiving resistor 50 Ω). *1. Resistor is provided only for the input code 2: Current signal (receiving resistor 50 Ω). *1 *1 *1 *1 1 2 4 5 7 8 1 2 4 5 7 8 *1 *1 *1 *1 • Switching Status When the switching command contact is switched from OFF to ON or from ON to OFF, the signal channel is switched only after all photo MOSFET relays turn on (closed). When the switching command contact is switched from OFF to ON or from ON to OFF, the signal channel is switched only after all photo MOSFET relays turn off (open). ■ INTERLOCKING SWITCHING CONTROL (single-pole contact) Single contact is used to switch from Signal Channel 1 (A1 – B1) to Signal Channel 2 (A2 – B1) and vice versa. CHANNEL 1 (A1) CHANNEL 2 (A2) Terminal 3 – 9 OFF (open) OFF ON Terminal 3 – 9 ON (closed) ON OFF Status LED turn on when the respective channels are alive. ■ INDEPENDENT SWITCHING CONTROL (double-pole contact) Double contacts are used to independently switch Signal Channel 1 (A1 – B1) and Signal Channel 2 (A2 – B1). CHANNEL 1 (A1) CHANNEL 2 (A2) Terminal 3 – 9 OFF (open) OFF ---- Terminal 3 – 9 ON (closed) ON ---- Terminal 6 – 9 OFF (open) ---- OFF Terminal 6 – 9 ON (closed) ---- ON Status LED turn on when the respective channels are alive. |
|
|
Ligação URL |
| ALLDATASHEET é útil para você? [ DONATE ] |
Sobre Alldatasheet | Publicidade | Contato conosco | Privacy Policy | Link para a ficha técnica | roca de Link | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |