| Os motores de busca de Datasheet de Componentes eletrônicos |
|
JSTB04B-PASK-1 Folha de dados(PDF) 12 Page - Microchip Technology |
|
|
|||||||||||||||||||||||||||||
JSTB04B-PASK-1 Folha de dados(HTML) 12 Page - Microchip Technology |
|
12 / 17 page ![]() 62EM1 – Programmable 62mm Electrical Series PRELIMINARY 62EM1 - 62mm Electrical Master 1 Spec Sheet V09 Page 12 of 17 Generic Sample Factory Settings AgileSwitch drivers are designed to provide safe, secure and efficient operation of the SiC MOSFET power module, as well as to provide unparalleled information on the condition of the overall system. Generic samples are set at the factory to perform certain actions (e.g. turn off the HI side or LO side of the SiC MOSFET) and to report that a fault occurred based on performance parameters that occur outside of default ranges. The tables below show the generic configuration. Performance & Interconnect Settings Parameter Generic Factory Setting Value Unit Rgon (Turn-on Gate Resistance) Populated 1.1 Ω Rgoff (Turn-off Gate Resistance) Populated 1.1 Ω Desaturation Time Enabled 1.5 µs Dead Time Enabled 1 µs Fault Reset Auto 5 ms DC Link Voltage Fault Enabled 900 V Temperature Fault Enabled 125 °C UVLO Primary Enabled 13.2 V OVLO Primary Enabled 16.5 V J1 (20 pin Control/Power Header) Populated J5 (2 pin Thermistor Header) Populated J6 (5 pin Main/Secondary Header) Not Populated J7 (4 pin Main/Secondary Header) Not Populated Fault and Monitoring Conditions Fault Condition/Action Generic Sample Default Trigger Values Action on IGBT if Active (Default Setting) HI Fault LO Fault All Faults NO FAULTS HIGH HIGH HIGH DSAT/UVLO – HI See Electrical Characteristics Turn Off HI & LO Side LOW HIGH LOW DSAT/UVLO – LO See Electrical Characteristics Turn Off HI &LO Side HIGH LOW LOW OVLO See Electrical Characteristics Turn Off HI & LO Side HIGH HIGH LOW Temperature Fault 125 °C Thermistor Monitor No Action HIGH HIGH LOW DC Link Voltage Fault DC Link Voltage above or below setting Turn Off HI & LO Side HIGH HIGH LOW Power On Configuration Fault* Failure to Configure Gate drivers Turn Off HI & LO Side LOW LOW LOW *After power up, if all Fault lines are LOW, then either there is a real fault (UVLO/DSAT) on both the HI and LO sides or there has been a software configuration failure. |
|
|
Ligação URL |
| ALLDATASHEET é útil para você? [ DONATE ] |
Sobre Alldatasheet | Publicidade | Contato conosco | Privacy Policy | Link para a ficha técnica | roca de Link | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |