Os motores de busca de Datasheet de Componentes eletrônicos
  Portuguese  ▼
ALLDATASHEETPT.COM

X  

TMP139AIYAHT Folha de dados(PDF) 46 Page - Texas Instruments

Click here to check the latest version.
Nome de Peças TMP139AIYAHT
Descrição Electrónicos  TMP139 0.5 째C Accuracy, JEDEC DDR5 Grade B, Digital Temperature Sensor With I2C and I3C Interface
PDF  58 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Fabricante Electrônico  TI [Texas Instruments]
Página de início  http://www.ti.com
Logo TI - Texas Instruments

TMP139AIYAHT Folha de dados(HTML) 46 Page - Texas Instruments

Back Button TMP139AIYAHT Datasheet HTML 42Page - Texas Instruments TMP139AIYAHT Datasheet HTML 43Page - Texas Instruments TMP139AIYAHT Datasheet HTML 44Page - Texas Instruments TMP139AIYAHT Datasheet HTML 45Page - Texas Instruments TMP139AIYAHT Datasheet HTML 46Page - Texas Instruments TMP139AIYAHT Datasheet HTML 47Page - Texas Instruments TMP139AIYAHT Datasheet HTML 48Page - Texas Instruments TMP139AIYAHT Datasheet HTML 49Page - Texas Instruments TMP139AIYAHT Datasheet HTML 50Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 46 / 58 page
background image
Table 7-35. MR51: Temperature Status Field Descriptions (continued)
Bit
Field
Type
Reset
Description
0
TS_HIGH_STATUS
R
0
Temperature sensor high status
0 = Temperature is below the limit set in registers MR29 and
MR28.
1 = Temperature is above the limit set in registers MR29 and
MR28.
7.6.24 MR52: Miscellaneous Error Status (address = 34h) [reset = 00h]
The MR52 register stores the status for PEC checksum failure when PEC mode is enabled and parity error on
the T-bit when the host writes to the device in I3C mode.
Return to Register Map.
Figure 7-70. MR52: Miscellaneous Error Status Register
7
6
5
4
3
2
1
0
Reserved
PEC_ERROR_S
TATUS
PAR_ERROR_S
TATUS
R-00h
R-0
R-0
Table 7-36. MR52: Miscellaneous Error Status Field Descriptions
Bit
Field
Type
Reset
Description
7:2
Reserved
R
00
Reserved
1
PEC_ERROR_STATUS
R
0
Packet error status.
0 = No PEC error.
1 = PEC error in one or more packets.
0
PAR_ERROR_STATUS
R
0
Parity check error status
0 = No parity error.
1 = Parity error in one or more bytes.
TMP139
SNIS217 – DECEMBER 2020
www.ti.com
46
Submit Document Feedback
Copyright © 2021 Texas Instruments Incorporated
Product Folder Links: TMP139



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58


Folha de dados Download

Go To PDF Page


Ligação URL



ALLDATASHEET é útil para você?  [ DONATE ] 

Sobre Alldatasheet   |   Publicidade   |   Contato conosco   |   Privacy Policy   |   Link para a ficha técnica    |   roca de Link   |   Lista de Fabricantes
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com