| Os motores de busca de Datasheet de Componentes eletrônicos |
|
ATR2805S/CH Folha de dados(PDF) 7 Page - International Rectifier |
|
|
|||||||||||||||||||||||||||||
ATR2805S/CH Folha de dados(HTML) 7 Page - International Rectifier |
|
7 / 12 page ![]() www.irf.com 7 ATR28XXS Series Table III. Electrical performance Characteristics - continued ATR2812S Limits Test Symbol Conditions -55 °C ≤ TC ≤ +125°C V IN = 28VDC ±5%, CL = 0 Unless otherwise specified Group A Subgroups Device Types Min Max Units Recovery time transient step line changes 5, 8, 9 TT LINE Input step 16V to/from 40VDC, I OUT = 2500mA 4,5,6 01 10 ms Turn on overshoot VTon OS I OUT =0 and 2500mA 4,5,6 01 800 mV pk Turn on delay 10 Ton D I OUT =0 and 2500mA 4,5,6 01 25 ms Load fault recovery 5, 10 Tr LF 4,5,6 01 25 ms Notes to Specifications 1 Parameter guaranteed by line and load regulation tests. 2 Bandwidth guaranteed by design. Tested for 20 KHz to 2 MHz. 3 Output voltage measured at load with remote sense leads connected across load. 4 Capacitive load may be any value from 0 to the maximum limit without compromising dc performance. A capacitive load in excess of the maximum limit will not disturb loop stability but may interfere with the operation of the load fault detection circuitry, appearing as a short circuit during turn on. 5 Parameter shall be tested as part of design characterization and after design or process changes. Thereafter parameters shall be guaranteed to the limits specified in table III. 6 An overload is that condition with a load in excess of the rated load but less than that necessary to trigger the short circuit protection and is the condition of maximum power dissipation. 7 Load step transition time between 2 and 10 microseconds. 8 Recovery time is measured from the initiation of the transient to where V OUT has returned to within ±1 percent of VOUT at 50 percent load. 9 Input step transition time between 2 and 10 microseconds. 10 Turn on delay time measurement is for either a step application of power at the input or the removal of a ground signal from the inhibit pin (pin 2) while power is applied to the input. |
|
|
Ligação URL |
| ALLDATASHEET é útil para você? [ DONATE ] |
Sobre Alldatasheet | Publicidade | Contato conosco | Privacy Policy | Link para a ficha técnica | roca de Link | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |