Os motores de busca de Datasheet de Componentes eletrônicos
  Portuguese  ▼
ALLDATASHEETPT.COM

X  

K-MD2-RFB-01F-01 Folha de dados(PDF) 6 Page - RFbeam Microwave GmbH

Nome de Peças K-MD2-RFB-01F-01
Descrição Electrónicos  Engineering Sample
PDF  23 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Fabricante Electrônico  RFBEAM [RFbeam Microwave GmbH]
Página de início  https://www.rfbeam.ch/
Logo RFBEAM - RFbeam Microwave GmbH

K-MD2-RFB-01F-01 Folha de dados(HTML) 6 Page - RFbeam Microwave GmbH

Back Button K-MD2-RFB-01F-01 Datasheet HTML 2Page - RFbeam Microwave GmbH K-MD2-RFB-01F-01 Datasheet HTML 3Page - RFbeam Microwave GmbH K-MD2-RFB-01F-01 Datasheet HTML 4Page - RFbeam Microwave GmbH K-MD2-RFB-01F-01 Datasheet HTML 5Page - RFbeam Microwave GmbH K-MD2-RFB-01F-01 Datasheet HTML 6Page - RFbeam Microwave GmbH K-MD2-RFB-01F-01 Datasheet HTML 7Page - RFbeam Microwave GmbH K-MD2-RFB-01F-01 Datasheet HTML 8Page - RFbeam Microwave GmbH K-MD2-RFB-01F-01 Datasheet HTML 9Page - RFbeam Microwave GmbH K-MD2-RFB-01F-01 Datasheet HTML 10Page - RFbeam Microwave GmbH Next Button
Zoom Inzoom in Zoom Outzoom out
 6 / 23 page
background image
©
RFbeam Microwave GmbH | Schuppisstrasse 7 | CH-9016 St. Gallen | www.rfbeam.ch | K-MD2 Engineering Sample | data sheet
07/2018 – Revision A | Page 6/23
THEORY OF OPERATION
The K-MD2 is configured to perform Frequency Mo-
dulated Continuous Wave (FMCW). With this modu-
lation the radar receives information about static and
moving objects.
In a typical FMCW radar system, the carrier frequency
is modulated with a digitally generated linear ramp. At
each step in the ramp, the received signal is demodu-
lated and the phase is sampled.
4 samples ignored
256 samples used
bandwidth
f
t
Frame
The K-MD2 is configured to sample 257 chirps per
frame but disregards the first chirp and uses only 256
chirps. Ignoring the first chirp is necessary to exclude
disturbances in the first chirp which are caused by
jumping to the start frequency.
First chirp ignored
256 chirps used
f
t
Chirp 0
Chirp 1
Chirp 2
Chirp 256
Figure 7: Frame generation
Figure 6: Ramp generation and sampling
Ramp
The K-MD2 is configured to use a saw tooth modula-
tion for the ramp. It samples 260 points and ignores
the first 4 samples. This means only the last 256
samples are used for processing. Ignoring the first
four samples will be done to eliminate the discontinui-
ty at start of the ramp.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23


Folha de dados Download

Go To PDF Page


Ligação URL



ALLDATASHEET é útil para você?  [ DONATE ] 

Sobre Alldatasheet   |   Publicidade   |   Contato conosco   |   Privacy Policy   |   Link para a ficha técnica    |   roca de Link   |   Lista de Fabricantes
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com