Os motores de busca de Datasheet de Componentes eletrônicos
  Portuguese  ▼
ALLDATASHEETPT.COM

X  

PTPS50602HFG/EM Folha de dados(PDF) 23 Page - Texas Instruments

Nome de Peças PTPS50602HFG/EM
Descrição Electrónicos  Radiation Hardened 3-V to 7-V Input, 12-A Single, 6-A Dual Output Synchronous Buck Converter
PDF  30 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Fabricante Electrônico  TI1 [Texas Instruments]
Página de início  http://www.ti.com
Logo TI1 - Texas Instruments

PTPS50602HFG/EM Folha de dados(HTML) 23 Page - Texas Instruments

Back Button PTPS50602HFG/EM Datasheet HTML 19Page - Texas Instruments PTPS50602HFG/EM Datasheet HTML 20Page - Texas Instruments PTPS50602HFG/EM Datasheet HTML 21Page - Texas Instruments PTPS50602HFG/EM Datasheet HTML 22Page - Texas Instruments PTPS50602HFG/EM Datasheet HTML 23Page - Texas Instruments PTPS50602HFG/EM Datasheet HTML 24Page - Texas Instruments PTPS50602HFG/EM Datasheet HTML 25Page - Texas Instruments PTPS50602HFG/EM Datasheet HTML 26Page - Texas Instruments PTPS50602HFG/EM Datasheet HTML 27Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 23 / 30 page
background image
C
OUT >
2 × I
O
f
SW ×
¿VOUT
L =
V
INMAX
F VOUT
I
O × KL
×
VOUT
V
INMAX × fSW
23
TPS50602-SP
www.ti.com
SLVSDJ9 – OCTOBER 2018
Product Folder Links: TPS50602-SP
Submit Documentation Feedback
Copyright © 2018, Texas Instruments Incorporated
Typical Application (continued)
8.2.3 Design Requirements
This example highlights a design for the TPS50601A-SP die (VOUT1) in the TPS50602-SP evaluation module in
Dual Output Configuration. For more details, please refer to the EVM user's guide (see SLVUB66). A few
parameters must be known in order to start the design process. These parameters are typically determined at the
system level. For this example, we start with the following known parameters:
Table 1. Design Parameters
DESIGN PARAMETER
EXAMPLE VALUE
Output voltage
2.5 V
Maximum output current
6 A
Transient response 1-A load step
ΔVOUT = 5%
Input voltage
5-V nominal, 4.5 V to 7 V
Output voltage ripple
20 mVp-p
Start input voltage (rising VIN)
4.5 V
Stop input voltage (falling VIN)
4.3 V
Switching frequency
500 kHz (internal oscillator)
8.2.4 Detailed Design Procedure
8.2.4.1 Operating Frequency
In this design, a switching frequency of 500 kHz is selected. Based on the Fixed Switching Frequency and
Synchronization (SYNC) section, the RT1 is left floating and the SYNC1 pin is used to drive the SYNC2 pin and
the RT2 pin must have a 95.3-kΩ resistor.
8.2.4.2 Output Inductor Selection
To calculate the value of the output inductor, use Equation 13. KL is a coefficient that represents the amount of
inductor ripple current relative to the maximum output current, IO. The inductor ripple current is filtered by the
output capacitor therefore, choosing high-inductor ripple currents impact the selection of the output capacitor
since the output capacitor must have a ripple current rating equal to or greater than the inductor ripple current. In
general, the inductor ripple value is at the discretion of the designer depending on specific system needs. Typical
values for KL range from 0.1 to 0.5. For low output currents, the value of KL could be increased to reduce the
value of the output inductor.
(13)
For this design example, use KL = 0.45 and the inductor value is calculated to be 1.8 µH for nominal VIN = 5 V.
8.2.4.3 Output Capacitor Selection
There are three primary considerations for selecting the value of the output capacitor. The output capacitor
determines the modulator pole, the output voltage ripple, and how the regulator responds to a large change in
load current. The output capacitance needs to be selected based on the more stringent of these three criteria.
The desired response to a large change in the load current is the first criteria. The output capacitor needs to
supply the load with current when the regulator can not. This situation would occur if there are desired hold-up
times for the regulator where the output capacitor must hold the output voltage above a certain level for a
specified amount of time after the input power is removed. The regulator is also temporarily not able to supply
sufficient output current if there is a large, fast increase in the current needs of the load such as a transition from
no load to full load. The output capacitor must be sized to supply the extra current to the load until the control
loop responds to the load change. Equation 14 shows the minimum output capacitance, from the electrical point
of view, necessary to accomplish this.
(14)



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30


Folha de dados Download

Go To PDF Page


Ligação URL



ALLDATASHEET é útil para você?  [ DONATE ] 

Sobre Alldatasheet   |   Publicidade   |   Contato conosco   |   Privacy Policy   |   Link para a ficha técnica    |   roca de Link   |   Lista de Fabricantes
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp