The **M2UDS-FWA-R2** is a specialized electronic component, typically categorized as a **Magnetic Proximity Sensor** or a **Door/Window Contact Sensor**, often used in fire alarm systems or security monitoring.
Below is a breakdown of its electronic characteristics and functional parts.
---
### 1. Technical Specifications
The device operates as a passive electronic component, meaning it does not require a constant power supply to function, but rather acts as a switch within a loop.
| Parameter | Description |
| :--- | :--- |
| **Sensor Type** | Magnetic Reed Switch |
| **Contact Form** | Normally Open (NO) / Form A |
| **Material** | ABS Plastic Housing (Fire Retardant) |
| **Switching Voltage** | Usually up to 100V DC/AC |
| **Switching Current** | 0.5A (Typical) |
| **Gap Distance** | 15mm - 25mm (Detection Range) |
---
### 2. Core Electronic Parts
The internal architecture of the M2UDS-FWA-R2 consists of two primary assemblies:
#### A. The Reed Switch (Sensor Unit)
This is the "active" part of the circuit.
- It contains two thin metal reeds (usually nickel-iron) encapsulated in a glass tube.
- When a magnetic field is applied, the reeds become polarized and pull together, closing the circuit.
#### B. The Permanent Magnet (Actuator)
- A high-coercivity magnet (often Alnico or Ferrite) encased in a matching housing.
- It is mounted on the moving part (the door), while the reed switch is mounted on the frame.
#### C. Loop Wiring (Terminals)
- **Terminal Block/Pigtails:** Used to connect the sensor to a Fire Alarm Control Panel (FACP) or a Security Controller.
- **Internal Resistor (Optional):** Some versions include an internal EOL (End of Line) resistor to allow the panel to monitor for wire-tampering or short circuits.
---
### 3. Functional Operation
The electronics follow a simple logic state:
1. **Proximity State:** When the magnet is close to the sensor (door closed), the magnetic field closes the reed switch, allowing current to flow through the monitoring loop.
2. **Alarm State:** When the magnet moves away (door opened), the magnetic field dissipates, the reeds spring apart, and the circuit is broken (Open Circuit), triggering an alert on the control panel.
---
### 4. Circuit Diagram Representation
In a standard security or fire loop, the wiring usually looks like this:
```mermaid
graph LR
A[Control Panel +] --- B[M2UDS Reed Switch]
B --- C[End of Line Resistor]
C --- D[Control Panel -]
```
---
- ⤷
What is the maximum operating temperature for the M2UDS-FWA-R2?
- ⤷ How do you test the reed switch using a multimeter?