The **M2RTS-R-DE-R2/N** is a specific model within a series of industrial signal conditioners/transmitters, typically manufactured by companies like **M-System**. This device is a RTD (Resistance Temperature Detector) transmitter designed to convert a temperature signal into a standardized analog output.
---
### 1. Model Breakdown (Nomenclature)
The alphanumeric code describes the specific electronic hardware configuration of the unit:
| Code Segment | Description | Specific Detail |
|:---|:---|:---|
| **M2RTS** | Series Name | Mini-M Series RTD Transmitter |
| **-R** | Power Input | 24V DC |
| **-DE** | Input Type | Pt 100 (DIN) temperature sensor |
| **-R2** | Output Type | 4 – 20 mA DC (Current Loop) |
| **-N** | Options | Special specification (often refers to specific calibration or coating) |
---
### 2. Technical Specifications
Below are the core electronic characteristics of the M2RTS-R-DE-R2/N:
#### Input Specifications (RTD)
* **Sensor Type:** Pt 100 (3-wire system).
* **Excitation Current:** Typically 2 mA.
* **Allowable Leadwire Resistance:** Usually max. 20 $\Omega$ per wire.
#### Output Specifications (Analog)
* **Signal:** 4 to 20 mA DC.
* **Load Resistance:** Max 600 $\Omega$.
* **Response Time:** $\leq$ 0.5 seconds (0 – 90%).
#### General Electronics
* **Isolation:** 3-way isolation (Input to Output to Power).
* **Isolation Resistance:** 100 M$\Omega$ at 500V DC.
* **Dielectric Strength:** 2000V AC @ 1 minute.
* **Accuracy:** $\pm$ 0.1% of span.
---
### 3. Wiring Diagram (Simplified)
To integrate this part into a circuit, the following terminal logic is generally used:
```text
[ Power Supply ] --- (+) Terminal 7 (24V DC)
--- (-) Terminal 8 (GND)
[ RTD Input ] --- Terminal 1 (A)
--- Terminal 2 (B)
--- Terminal 3 (B)
[ Current Output ]-- (+) Terminal 5
--- (-) Terminal 6
```
---
### 4. Key Electronic Features
* **Linearization:** The internal circuitry automatically compensates for the non-linear resistance characteristics of the Platinum sensor to ensure a linear 4-20mA output relative to temperature.
* **Burnout Protection:** The device includes a "Burnout" feature. If the RTD wire breaks, the output will typically drive to a "High" (above 20mA) or "Low" (below 4mA) state to alert the control system (PLC/DCS).
* **Zero/Span Adjustment:** Physical potentiometers are usually located on the front of the module to allow manual calibration of the 0% and 100% points.
- ⤷
What is the maximum temperature range supported by the DE input configuration?
- ⤷ How does the 3-way isolation benefit industrial control systems?
- ⤷ Is there a specific DIN rail mounting requirement for this model?