Os motores de busca de Datasheet de Componentes eletrônicos
  Portuguese  ▼
ALLDATASHEETPT.COM

X  

  • FLM-4WB-R

  • AI
    The **FLM-4WB-R** is a specialized electronic module manufactured by **Bosch**, primarily used in fire alarm systems. It functions as a **Field Loop Module (FLM)** designed to monitor and interface conventional 4-wire smoke detectors with a digital addressable fire alarm loop. --- ## 1. Technical Specifications The following table outlines the core electrical and mechanical characteristics of the FLM-4WB-R: | Feature | Specification | | :--- | :--- | | **Input Voltage (LSN)** | 15 V DC to 33 V DC | | **External Power Supply** | 24 V DC (nominal) | | **Max. Current Consumption** | Approx. 0.1 mA (on LSN loop) | | **EOL Resistance** | 3.9 kΩ (standard) | | **Protection Class** | IP 30 | | **Housing Material** | ABS Plastic (Flame retardant) | --- ## 2. Key Electronic Components & Functions ### A. LSN Interface (Local Security Network) The module acts as a bridge between the **LSN bus** (the "brain" of the fire panel) and conventional detectors. It contains integrated circuits (ICs) that handle: * **Addressing:** Unique identification of the module on the loop. * **Data Transmission:** Sending status updates (Alarm, Trouble, Normal) back to the control panel. ### B. Relay Outputs (Power Reset) Since 4-wire smoke detectors require a constant power source, they must be "reset" by momentarily cutting power after an alarm. The FLM-4WB-R includes an **integrated relay** that: * Interrupts the 24V power supply to the detectors upon a reset command from the panel. * Ensures the sensors are cleared of smoke particles and ready for re-activation. ### C. Monitoring Circuitry The module monitors the conventional line for two specific electrical states: 1. **Alarm State:** Detected by a drop in resistance/increase in current when a detector triggers. 2. **Trouble State:** Detected via the **End-of-Line (EOL)** resistor. If a wire is cut, the module senses an open circuit and reports a fault. --- ## 3. Wiring Configuration The "4WB" in the model name refers to **4-Wire Bus/Branching**. Below is the typical connectivity logic: ```mermaid graph TD A[Fire Alarm Panel - LSN] -->|Data + Power| B(FLM-4WB-R) C[External 24V DC PS] -->|Power| B B -->|4-Wire Line| D[Conventional Detector 1] D -->|4-Wire Line| E[Conventional Detector 2] E -->|Terminator| F[EOL Resistor 3.9k] ``` --- ## 4. Key Advantages * **Retrofitting:** Allows old conventional 4-wire detectors to work with modern digital Bosch panels. * **Isolation:** Usually features integrated short-circuit isolators to maintain loop integrity if a wire is damaged. * **LED Feedback:** Includes a red LED indicator that flashes to indicate communication or stays solid to indicate an alarm state.
    ✨ Follow-up Questions
    • ⤷ What is the difference between the FLM-4WB-R and a standard 2-wire monitor module?
    • ⤷ How do you address this module using the rotary switches?
    • ⤷ What are the specific wiring requirements for the EOL resistor in this module?