Os motores de busca de Datasheet de Componentes eletrônicos
  Portuguese  ▼
ALLDATASHEETPT.COM

X  

H8S/2111B Folha de dados(PDF) 296 Page - Renesas Technology Corp

Nome de Peças H8S/2111B
Descrição Electrónicos  16-Bit Single-Chip Microcomputer
PDF  582 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Fabricante Electrônico  RENESAS [Renesas Technology Corp]
Página de início  http://www.renesas.com
Logo RENESAS - Renesas Technology Corp

H8S/2111B Folha de dados(HTML) 296 Page - Renesas Technology Corp

Back Button H8S/2111B Datasheet HTML 292Page - Renesas Technology Corp H8S/2111B Datasheet HTML 293Page - Renesas Technology Corp H8S/2111B Datasheet HTML 294Page - Renesas Technology Corp H8S/2111B Datasheet HTML 295Page - Renesas Technology Corp H8S/2111B Datasheet HTML 296Page - Renesas Technology Corp H8S/2111B Datasheet HTML 297Page - Renesas Technology Corp H8S/2111B Datasheet HTML 298Page - Renesas Technology Corp H8S/2111B Datasheet HTML 299Page - Renesas Technology Corp H8S/2111B Datasheet HTML 300Page - Renesas Technology Corp Next Button
Zoom Inzoom in Zoom Outzoom out
 296 / 582 page
background image
Rev. 1.00, 05/04, page 262 of 544
Yes
<End>
[1]
No
Initialization
Start reception
No
Yes
[4]
Clear RE bit in SCR to 0
Error processing
(Continued on
next page)
[5]
No
Yes
FER
∨ ORER = 1
RDRF = 1
All data received?
Set MPIE bit in SCR to 1
[2]
Read ORER and FER flags in SSR
Read RDRF flag in SSR
[3]
Read receive data in RDR
No
Yes
This station’s ID?
Read ORER and FER flags in SSR
Yes
No
Read RDRF flag in SSR
No
Yes
FER
∨ ORER = 1
Read receive data in RDR
RDRF = 1
[1]
SCI initialization:
The RxD pin is automatically designated as
the receive data input pin.
[2]
ID reception cycle:
Set the MPIE bit in SCR to 1.
[3]
SCI status check, ID reception and
comparison:
Read SSR and check that the RDRF flag is
set to 1, then read the receive data in RDR
and compare it with this station’s ID.
If the data is not this station’s ID, set the MPIE
bit to 1 again, and clear the RDRF flag to 0.
If the data is this station’s ID, clear the RDRF
flag to 0.
[4]
SCI status check and data reception:
Read SSR and check that the RDRF flag is
set to 1, then read the data in RDR.
[5]
Receive error processing and break detection:
If a receive error occurs, read the ORER and
FER flags in SSR to identify the error. After
performing the appropriate error processing,
ensure that the ORER and FER flags are all
cleared to 0.
Reception cannot be resumed if either of
these flags is set to 1.
In the case of a framing error, a break can be
detected by reading the RxD pin value.
[Legend]
∨ : Logical OR
Figure 12.13 Sample Multiprocessor Serial Reception Flowchart (1)



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100  ...More


Folha de dados Download

Go To PDF Page


Ligação URL



ALLDATASHEET é útil para você?  [ DONATE ] 

Sobre Alldatasheet   |   Publicidade   |   Contato conosco   |   Privacy Policy   |   Link para a ficha técnica    |   roca de Link   |   Lista de Fabricantes
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com