Back Button H8/3028F Datasheet HTML 529Page - Renesas Technology Corp H8/3028F Datasheet HTML 530Page - Renesas Technology Corp H8/3028F Datasheet HTML 531Page - Renesas Technology Corp H8/3028F Datasheet HTML 532Page - Renesas Technology Corp H8/3028F Datasheet HTML 533Page - Renesas Technology Corp H8/3028F Datasheet HTML 534Page - Renesas Technology Corp H8/3028F Datasheet HTML 535Page - Renesas Technology Corp H8/3028F Datasheet HTML 536Page - Renesas Technology Corp H8/3028F Datasheet HTML 537Page - Renesas Technology Corp Next Button
Zoom Inzoom in Zoom Outzoom out
 533 / 923 page
background image
Rev. 2.00, 09/03, page 503 of 890
<End>
(3)
Error handling
Overrun error handling
Clear ORER flag to 0 in SSR
Figure 13.18 Sample Flowchart for Serial Receiving (2)
In receiving, the SCI operates as follows:
• The SCI synchronizes with serial clock input or output and synchronizes internally.
• Receive data is stored in RSR in order from LSB to MSB.
After receiving the data, the SCI checks that the RDRF flag is 0, so that receive data can be
transferred from RSR to RDR. If this check passes, the RDRF flag is set to 1 and the received
data is stored in RDR. If the checks fails (receive error), the SCI operates as shown in table
13.11.
When a receive error has been identified in the error check, subsequent transmit and receive
operations are disabled.
• When the RDRF flag is set to 1, if the RIE bit is set to 1 in SCR, a receive-data-full interrupt
(RXI) is requested. If the ORER flag is set to 1 and the RIE bit in SCR is also set to 1, a
receive-error interrupt (ERI) is requested.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100  ...More


Folha de dados Download

Go To PDF Page


Ligação URL



ALLDATASHEET é útil para você?  [ DONATE ] 

Sobre Alldatasheet   |   Publicidade   |   Contato conosco   |   Privacy Policy   |   Link para a ficha técnica    |   roca de Link   |   Lista de Fabricantes
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com