540 / 1250 page ![]() Section 13 Serial Communication Interface (SCI) Rev. 2.00 Aug. 20, 2008 Page 492 of 1198 REJ09B0403-0200 13.9.6 Restrictions on Using DTC When the external clock source is used as a synchronization clock, update TDR by the DTC and wait for at least five φ clock cycles before allowing the transmit clock to be input. If the transmit clock is input within four clock cycles after TDR modification, the SCI may malfunction (figure 13.33). When using the DTC to read RDR, be sure to set the receive end interrupt source (RXI) as a DTC activation source. t D0 LSB Serial data SCK D1 D3 D4 D5 D2 D6 D7 Note: When external clock is supplied, t must be more than four clock cycles. TDRE Figure 13.33 Sample Transmission using DTC in Clock Synchronous Mode |
|
Ligação URL |
| ALLDATASHEET é útil para você? [ DONATE ] |
Sobre Alldatasheet | Publicidade | Contato conosco | Privacy Policy | Link para a ficha técnica | roca de Link | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|