111 / 187 page ![]() IS25LE02GG IS25WE02GG Integrated Silicon Solution, Inc.- www.issi.com 111 Rev. A1 10/02/2025 8.31 CLEAR EXTENDED READ REGISTER OPERATION (CLERP, 82h) A Clear Extended Read Register (CLERP) instruction clears PROT_E, P_ERR, and E_ERR error bits in the Extended Read Register to “0” when the error bits are set to “1”. Once the error bits are set to “1”, they remains set to “1” until they are cleared to “0” with a CLERP command. Figure 8.68 Clear Extended Read Register Sequence In SPI Mode Instruction = 82h CE# SCK SI 0 1 2 3 4 5 6 7 Mode 3 Mode 0 SO High Impedance Figure 8.69 Clear Extended Read Register Sequence In QPI Mode 82h CE# SCK IO[3:0] 0 1 Mode 3 Mode 0 |
|
Ligação URL |
| ALLDATASHEET é útil para você? [ DONATE ] |
Sobre Alldatasheet | Publicidade | Contato conosco | Privacy Policy | Link para a ficha técnica | roca de Link | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|