Os motores de busca de Datasheet de Componentes eletrônicos
  Portuguese  ▼
ALLDATASHEETPT.COM

X  

SIM800 Folha de dados(PDF) 191 Page - SIMCom

Nome de Peças SIM800
Descrição Electrónicos  SIM800 Series AT Command Manual
PDF  380 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Fabricante Electrônico  SIMCOM [SIMCom]
Página de início  https://www.simcom.com
Logo SIMCOM - SIMCom

SIM800 Folha de dados(HTML) 191 Page - SIMCom

Back Button SIM800 Datasheet HTML 187Page - SIMCom SIM800 Datasheet HTML 188Page - SIMCom SIM800 Datasheet HTML 189Page - SIMCom SIM800 Datasheet HTML 190Page - SIMCom SIM800 Datasheet HTML 191Page - SIMCom SIM800 Datasheet HTML 192Page - SIMCom SIM800 Datasheet HTML 193Page - SIMCom SIM800 Datasheet HTML 194Page - SIMCom SIM800 Datasheet HTML 195Page - SIMCom Next Button
Zoom Inzoom in Zoom Outzoom out
 191 / 380 page
background image
Smart Machine Smart Decision
SIM800 Series_AT Command Manual_V1.09
191
2015-08-03
<display>
0 Report jamming status via URC every 3000ms. (only
when <mode> is set to “1” or “3”)
1 Report jamming status via URC when jamming status
changed.(only when <mode> is set to “1” or “3”)
Parameter
Saving
Mode
NO_SAVE
Max Response Time
-
Reference
Note
When you query jamming detection status after enable jamming
detection mode, you will get the URC of the format below:
+SJDR:1,<mode>,<var>,<display>,<result>
<result>=0, means no jamming.
<result>=1, means jamming is detected.
<result>=2, means industrial interference is detected.
“+SJDR: INTERFERENCE DETECTED” indicates industrial
interference which signifies unintentional radio link disturbances by
strong industrial radio sources.
Jamming detection PIN is designed to indicate jamming by
outputting different level. When jamming is detected, the PIN will
output a high level, otherwise, it will output a low level.
Jamming detection PIN is different among SIM800 series project,
please refer to chapter 21 for details.
6.2.59 AT+CPCMCFG
Set PCM Parameter
AT+CPCMCFG
Set PCM Parameter
Response
+CPCMCFG: (0-1)
OK
Test Command
AT+CPCMCFG
=?
Parameters
See Write Command
Response
+CPCMCFG: <format>
OK
Read Command
AT+CPCMCFG
?
Parameters
See Write Command
Write Command
AT+CPCMCFG
=<format>
Response
OK
ERROR



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100  ...More


Folha de dados Download

Go To PDF Page


Ligação URL



ALLDATASHEET é útil para você?  [ DONATE ] 

Sobre Alldatasheet   |   Publicidade   |   Contato conosco   |   Privacy Policy   |   Link para a ficha técnica    |   roca de Link   |   Lista de Fabricantes
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com