Os motores de busca de Datasheet de Componentes eletrônicos
  Portuguese  ▼
ALLDATASHEETPT.COM

X  

EXQ125-48S12J Datasheet with Chat AI
  • AIauthorized

    Hello, Please ask a question about EXQ125-48S12J Datasheet

  • # Example questions: ➢ What safety certifications does the exq125 series have?
    ➢ What is the minimum load requirement for the exq125 series?
    ➢ What is the input voltage range for the exq125 series?

  • Part No.EXQ125-48S12J
    ManufacturerARTESYN
    Size97 Kbytes
    Pages3 pages
    Description36-100 W High Efficiency DC/DC Converters
    Datasheet Summary with AI

    1. General Overview & Purpose

    ️· Product: Artesyn EXQ125 series of isolated DC-DC converters.
    ️· Type: Open-frame, industry-standard quarter-brick format.
    ️· Purpose: Designed for inclusion in other equipment, *not* as a standalone product. Primarily aimed at applications needing high efficiency and high output current at low voltages.
    ️· Power Range: Up to 100 Watts.
    ️· Input Voltage: 33 Vdc to 75 Vdc.
    ️· Output Voltages: Available in 1.2V, 1.5V, 1.8V, 2.5V, 5V, 12V, and 3.3V options.
    ️· Warranty: 2-year warranty.

    2. Technical Specifications (Key Numbers)

    ️· Output Voltage Adjustment: 90% to 110% of nominal.
    ️· Set Point Accuracy: ±1.5% max.
    ️· Line Regulation: ±0.1% max.
    ️· Load Regulation: ±0.2% max.
    ️· Minimum Load: 0 A.
    ️· Efficiency (Typical): Ranges from 86.5% to 93% depending on the model.
    ️· Input Fusing: Recommended 5 A HRC 200 V rated fuse.

    3. Safety & Compliance

    ️· Safety Approvals: UL/cUL1950, TÜV Rheinland, CB Scheme.
    ️· EMC (Electromagnetic Compatibility):
    - Conducted Emissions: Meets Level A and Level B *with external components*.
    - Radiated Emissions: Level B
    - Immunity Standards: EN61000-4-2 (ESD), EN61000-4-3 (Radiated Field), EN61000-4-6 (Conducted Power)

    4. Physical & Connectivity

    ️· Form Factor: Quarter-brick (industry standard)
    ️· Pinout:
    - Pin 1: +Vin
    - Pin 2: On/Off
    - Pin 3: -Vin
    - Pin 4: -Vout
    - Pin 5: -Sense
    - Pin 6: Trim
    - Pin 7: +Sense
    - Pin 8: +Vout

    5. Important Notes & Cautions

    ️· Professional Installation: Intended for installation by trained professionals only.
    ️· External Components: May require external components to meet EMC requirements (specifically for conducted emissions).
    ️· Application Note: See Application Note 118 for more information on external components and filtering.
    ️· Hazardous Voltages/Temperatures: Contains hazardous voltages and temperatures; ensure unit is not user accessible.
    ️· RoHS Compliance: RoHS compliant versions available (check with sales representative).
    ️· Model Options: Not all options are supported by all models (check the online model number search tool).

    1. General Overview & Purpose

    ️· Product: Artesyn EXQ125 series of isolated DC-DC converters.
    ️· Type: Open-frame, industry-standard quarter-brick format.
    ️· Purpose: Designed for inclusion in other equipment, *not* as a standalone product. Primarily aimed at applications needing high efficiency and high output current at low voltages.
    ️· Power Range: Up to 100 Watts.
    ️· Input Voltage: 33 Vdc to 75 Vdc.
    ️· Output Voltages: Available in 1.2V, 1.5V, 1.8V, 2.5V, 5V, 12V, and 3.3V options.
    ️· Warranty: 2-year warranty.

    2. Technical Specifications (Key Numbers)

    ️· Output Voltage Adjustment: 90% to 110% of nominal.
    ️· Set Point Accuracy: ±1.5% max.
    ️· Line Regulation: ±0.1% max.
    ️· Load Regulation: ±0.2% max.
    ️· Minimum Load: 0 A.
    ️· Efficiency (Typical): Ranges from 86.5% to 93% depending on the model.
    ️· Input Fusing: Recommended 5 A HRC 200 V rated fuse.

    3. Safety & Compliance

    ️· Safety Approvals: UL/cUL1950, TÜV Rheinland, CB Scheme.
    ️· EMC (Electromagnetic Compatibility):
    - Conducted Emissions: Meets Level A and Level B *with external components*.
    - Radiated Emissions: Level B
    - Immunity Standards: EN61000-4-2 (ESD), EN61000-4-3 (Radiated Field), EN61000-4-6 (Conducted Power)

    4. Physical & Connectivity

    ️· Form Factor: Quarter-brick (industry standard)
    ️· Pinout:
    - Pin 1: +Vin
    - Pin 2: On/Off
    - Pin 3: -Vin
    - Pin 4: -Vout
    - Pin 5: -Sense
    - Pin 6: Trim
    - Pin 7: +Sense
    - Pin 8: +Vout

    5. Important Notes & Cautions

    ️· Professional Installation: Intended for installation by trained professionals only.
    ️· External Components: May require external components to meet EMC requirements (specifically for conducted emissions).
    ️· Application Note: See Application Note 118 for more information on external components and filtering.
    ️· Hazardous Voltages/Temperatures: Contains hazardous voltages and temperatures; ensure unit is not user accessible.
    ️· RoHS Compliance: RoHS compliant versions available (check with sales representative).
    ️· Model Options: Not all options are supported by all models (check the online model number search tool).

    Part No.EXQ125-48S12J
    ManufacturerARTESYN
    Size97 Kbytes
    Pages3 pages
    Description36-100 W High Efficiency DC/DC Converters
    ALLDATASHEET é útil para você?  [ DONATE ] 

    Sobre Alldatasheet   |   Publicidade   |   Contato conosco   |   Privacy Policy   |   Link para a ficha técnica    |   roca de Link   |   Lista de Fabricantes
    All Rights Reserved©Alldatasheet.com


    Mirror Sites
    English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
    Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
    Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
    Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
    Family Site : ic2ic.com  |   icmetro.com