Os motores de busca de Datasheet de Componentes eletrônicos
  Portuguese  ▼
ALLDATASHEETPT.COM

X  

LC2-124-B/K Datasheet with Chat AI
  • AIauthorized

    Hello, Please ask a question about LC2-124-B/K Datasheet

  • # Example questions: ➢ What are the available output voltage ranges for the lc2 strain gauge transmitter, and what is the minimum load resistance required for the 0-10 mv dc output?
    ➢ Describe the power input specifications for both ac and dc power options, including the acceptable voltage ranges and maximum ripple for dc input.
    ➢ What options are available for customizing the lc2, specifically concerning input signal indication and response time, and what does the '/q' option allow for?

  • Part No.LC2-124-B/K
    ManufacturerMSYSTEM
    Size110 Kbytes
    Pages3 pages
    DescriptionPlug-in Signal Conditioners M-UNIT
    Datasheet Summary with AI

    1. Product Overview:

    ️· Product: M-Unit LC2 Strain Gauge Transmitter (Plug-in Signal Conditioner)
    ️· Purpose: To convert strain gauge signals into electrical signals (current or voltage) suitable for monitoring and control systems.
    ️· Type: Plug-in signal conditioner (presumably for use with a compatible M-Unit system).

    2. Ordering Information & Model Number:

    ️· Model Number: LC2–[1][2]–[3][4]
    - [1]: Input Strain Gauge: Specifies the input sensitivity range. Options include: 1mV/V, 1.25mV/V, 1.5mV/V, 2mV/V, 3mV/V, 4mV/V, 5mV/V, 10mV/V, 20mV/V, or "0" (specify).
    - [2]: Output: Specifies the output type. Options include:
    ■ Current: 4-20mA, 2-10mA, 1-5mA, 0-20mA, 0-16mA, 0-10mA, 0-1mA. Option "Z" allows specification of a custom current range.
    ■ Voltage: 0-10mV, 0-100mV, 0-1V, 0-10V, 0-5V, 1-5V, -10 to +10V, -5 to +5V. Option "0" allows specification of a custom voltage range.
    - [3]: Power Input: Specifies the power supply voltage. Options include: 100VAC, 110VAC, 115VAC, 120VAC, 200VAC, 220VAC, and 24VDC.
    - [4]: Options: Allows for customization of features. Options include:
    ■ Input Signal Indicator (/E – with display)
    ■ Response Time (/K – Fast Response)
    ■ Coating (/C01, /C02, /C03 - Silicone, Polyurethane, Rubber)
    ■ Terminal Screw Material (/S01 - Stainless Steel)

    3. Technical Specifications & Features:

    ️· Input:
    - Accepts signals from strain gauges.
    - Input Sensitivity Range specified by the [1] code in the model number.
    - Allowable Lead Wire Resistance: Limited to reduce measurement errors.
    ️· Output:
    - Current or Voltage output (specified by the [2] code)
    - Load Resistance limits specified for current outputs.
    ️· Power: Specified by [3] code.
    ️· Environment:
    - Operating Temperature: -5 to +60°C (23 to 140°F)
    - Operating Humidity: 30 to 90% RH (non-condensing)
    ️· Performance:
    - Accuracy: ±0.1% of span
    - Display Accuracy: ± (0.1 % of FS + 1 digit)
    - Temperature Coefficient: ±0.015%/°C
    - Dielectric Strength: High voltage isolation for safety.
    ️· Connections: M3.5 screw terminals.
    ️· Remote Sensing: Includes a remote sensing connection for accurate measurements with long lead wires.
    ️· Dimensions: A diagram is present.

    4. Key Considerations:

    ️· Remote Sensing: Crucial for minimizing errors with long lead wires.
    ️· Load Resistance: Adhere to specified load resistance limits to avoid damage or inaccurate readings.
    ️· Power Supply: Select the appropriate power supply voltage according to the [3] code in the model number.
    ️· Customization: Options allow for tailoring the transmitter to specific application requirements.

    1. Product Overview:

    ️· Product: M-Unit LC2 Strain Gauge Transmitter (Plug-in Signal Conditioner)
    ️· Purpose: To convert strain gauge signals into electrical signals (current or voltage) suitable for monitoring and control systems.
    ️· Type: Plug-in signal conditioner (presumably for use with a compatible M-Unit system).

    2. Ordering Information & Model Number:

    ️· Model Number: LC2–[1][2]–[3][4]
    - [1]: Input Strain Gauge: Specifies the input sensitivity range. Options include: 1mV/V, 1.25mV/V, 1.5mV/V, 2mV/V, 3mV/V, 4mV/V, 5mV/V, 10mV/V, 20mV/V, or "0" (specify).
    - [2]: Output: Specifies the output type. Options include:
    ■ Current: 4-20mA, 2-10mA, 1-5mA, 0-20mA, 0-16mA, 0-10mA, 0-1mA. Option "Z" allows specification of a custom current range.
    ■ Voltage: 0-10mV, 0-100mV, 0-1V, 0-10V, 0-5V, 1-5V, -10 to +10V, -5 to +5V. Option "0" allows specification of a custom voltage range.
    - [3]: Power Input: Specifies the power supply voltage. Options include: 100VAC, 110VAC, 115VAC, 120VAC, 200VAC, 220VAC, and 24VDC.
    - [4]: Options: Allows for customization of features. Options include:
    ■ Input Signal Indicator (/E – with display)
    ■ Response Time (/K – Fast Response)
    ■ Coating (/C01, /C02, /C03 - Silicone, Polyurethane, Rubber)
    ■ Terminal Screw Material (/S01 - Stainless Steel)

    3. Technical Specifications & Features:

    ️· Input:
    - Accepts signals from strain gauges.
    - Input Sensitivity Range specified by the [1] code in the model number.
    - Allowable Lead Wire Resistance: Limited to reduce measurement errors.
    ️· Output:
    - Current or Voltage output (specified by the [2] code)
    - Load Resistance limits specified for current outputs.
    ️· Power: Specified by [3] code.
    ️· Environment:
    - Operating Temperature: -5 to +60°C (23 to 140°F)
    - Operating Humidity: 30 to 90% RH (non-condensing)
    ️· Performance:
    - Accuracy: ±0.1% of span
    - Display Accuracy: ± (0.1 % of FS + 1 digit)
    - Temperature Coefficient: ±0.015%/°C
    - Dielectric Strength: High voltage isolation for safety.
    ️· Connections: M3.5 screw terminals.
    ️· Remote Sensing: Includes a remote sensing connection for accurate measurements with long lead wires.
    ️· Dimensions: A diagram is present.

    4. Key Considerations:

    ️· Remote Sensing: Crucial for minimizing errors with long lead wires.
    ️· Load Resistance: Adhere to specified load resistance limits to avoid damage or inaccurate readings.
    ️· Power Supply: Select the appropriate power supply voltage according to the [3] code in the model number.
    ️· Customization: Options allow for tailoring the transmitter to specific application requirements.

    Part No.LC2-124-B/K
    ManufacturerMSYSTEM
    Size110 Kbytes
    Pages3 pages
    DescriptionPlug-in Signal Conditioners M-UNIT
    ALLDATASHEET é útil para você?  [ DONATE ] 

    Sobre Alldatasheet   |   Publicidade   |   Contato conosco   |   Privacy Policy   |   Link para a ficha técnica    |   roca de Link   |   Lista de Fabricantes
    All Rights Reserved©Alldatasheet.com


    Mirror Sites
    English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
    Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
    Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
    Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
    Family Site : ic2ic.com  |   icmetro.com